Hi Shine Online UPS , 1 kva to 100 kva are Manufactured in India , Registered with MES , DGSnD , iso 9001 , iso 14001 , ce certified , bis registered Manufacturer ,,,............. Online Ups are in built Isolation transformer for type .. 1............ three phase AC input and three phase Ac output .. 2......... Three phase Ac input and Single Phase Ac output.... 3......... Single phase Ac Input and single phase Ac output......... 4,............. hybrid option of online ups with connection of solar energy, ,,,......... Registration certificate and test reports are provided on Request .. ............ we also provide comprehensive annual maintenance contract of Online UPS , Line Interactive UPS , Inverter , battery Chargers and Servo Stabilizers or Servo Motor Operated Line Voltage . ............we also provide maintenance at onsite also ................. HI SHINE UPS, Inverter , servo stabilizer , battery chargers , solar inverter MADE IN INDIA ARE DESIGNED WITH LATEST TECHNOLOGY..
Other Specifications Download Specification | |
---|---|
Rating In KVA | 20 KVA |
Technology | IGBT-PWM |
Input Power | Three phase 300 V - 450V sinewave,50Hz |
Output Power | 3 phase 400 V ±1% with alternative user setable setting of 380V+-1%,50Hz |
Backup Time | 120 Minutes |
Minimum VAH | 64000 VAH |
Voltage Regulation From No Load To Full Load | 1 % |
Inbuilt Isolation Transformer | Yes |
20% Overload Limit For Minimum 10 Minutes | Yes |
50% Overload Limit For Minimum 1 Minutes | Yes |
Total Harmonic Distortion(THD) | 2 % |
Overall Efficiency | 93 % |
Type Of Battery | SMF-VRLA conforming to JISC:8702(Pt.I,II&III) |
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted | 1.2 mm |
Degree Of Protection | IP21 |
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal | Yes |
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. | Yes |
Maximum Overshoot And Under Shoot Of Output Rated Voltage | 4 |
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage | Yes |
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current | Yes |
Movable Trolly For Batteries | With |
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs | Yes |
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) | Yes |
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. | Yes |
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. | Yes |
Type Test Certificate No. | 00223K |
Type Test Certificate Date | 2015 |
Name Of Lab | NTH |
Address Of Lab | CHENNAI ,INDIA |
Supply & Commissioning | AS per requirement |
Warranty | 1 Years |