× All the transactions performed on 2.0 is available here. To access Market click "Home".

apc 40 kva online ups parallel capable with 60 minutes backup (apc make)(galaxy 5500)

` 1,180,000.00

  • MRP: `1450000.00

40 KVA state-of-the-art three-phase power protection designed to meet a wide range of requirements from medium data centers to industrial and facilities applications, Upgradable power ranges, Internal maintenance bypass, Parallel capable.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM with inbuilt isolation transformer
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
  • Minimum VAH - 400 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 40 KVA
Technology MOSFET-PWM with inbuilt isolation transformer
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power 3 phase 400 V 1 with alternative user setable setting of 380V+-1,50Hz
Backup Time 60 Minutes
Minimum VAH 400 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 93 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. CRS2015-0532/R-83000450
Type Test Certificate Date 14-06-2017
Name Of Lab BUREAU OF INDIAN STANDARDS
Address Of Lab 9 Bahadur Shah Zafar Marg, New Delhi- 110002,India
Supply & Commissioning YES
Warranty 1 Years

Price Dekho Price Dekho Price List in india