100 MHz Mixed Signal Oscilloscopes MSO2012B..
Other Specifications Download Specification | |
---|---|
Type | Mixed Signal |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 2 Number |
Digital Channels | Yes |
No. Of Digital Channels | 16 Number |
Record Length Per Digital Channel Simultaneously | 1 GS/sec |
Sampling Rate Per Digital Channel Simultaneously | 0.5 Mega Points |
Min. Detectable Pulse Width | 5 ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 2mV/Div to 5 V/Div |
Vertical Resolution | 8 bits |
Coupling | AC,DC,GND |
Time Base Range | 4ns to 100s |
Trigger Types | Edge,Pulsewidth,Runt,Logic,Seup and Hold,Rise/Fall time,Video,Parallel |
Measurements | Period, Frequency, Delay, Rise Time,Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | No |
In-built Function Generator | No |
Acquisition Modes | Sample,Peakdetect,Averaging,Roll |
Display Type | Colour |
Display Size | 18 CM |
I/O Interface | USB |
Standard Accessories To Be Supplied | 2 Passive Probes of 100MHz, 16-channel logic probe and accessory kit , Documentaion CD,manual,Power cord, Calibration Certificate |
Operating Temperature Range | 0 C to +50 C Degree C |
Operating Humidity (RH) | 5 to 60 % |
Power Supply | 230V +- 10 , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NTH(SR)/EL(C)/2013/229(B) |
Test Report Date | 07.10.2013 |
Name Of The Lab | NTH,Chennai |
Warranty | 5 Year |
Real Time Bandwidth | 100 MHz |
Record Length Per Analog Channel Simultaneously | 1 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1 GS/sec |
Waveform Update Rate | 5000 Waveforms/ |
Time Base Accuracy | 25 PPM |