The FCA3000 Serious Timer/Counter/Analyzer Series pack many different functions into one feature-rich instrument. With industry-leading frequency and time resolution, the FCA Series comes standard with deep internal memory and a fast data transfer rate of 250k Samples/s to internal memory. In addition, the multi-parameter display shows auxiliary measurements alongside your main measurement to provide you with the results you need at a glance. With the industrys most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal..
Other Specifications Download Specification | |
---|---|
Frequency Range | 2 mHz to 3 GHz |
No. Of Channels | 2 No. |
Input Connector | BNC & N connector |
Type Of Input Signal | Burst, AM, FM and Noise Signal etc. |
Resolution | 10 or better Digit |
Input Impedance | 1 Mega Ohm |
Trigger Slope | Positive |
Display Type | Backlit (LCD Graphics Screen for Menu Control, Numerical Read Output & Status Information. |
Measurement | Frequency Period, Time, Phase, Volt,Duty Cycle, Pulse, Rise Time |
Indication | Frequency Level Status Indication (Bar Graph, Histogram) |
No. Of Digits | Programmable |
Time Base Type | OCXO |
Gate Time | 20 ns to 1000 s |
Single Shot Time Resolution | 100 Pico Sec |
Calibration | Electronic |
Aging Rate Per Year (AS Declared By The OEM) | 2 PPM |
Temperature Stability At 26 Degree C | 0.02 PPM |
Interface | GPIB & USB |
Operating Temperature | 0 to 50 Degree C |
Storage Temperature | -40 C to +71 C Degree C |
Short Warm Up Time | 45 Minutes |
Power Rating | 90 Watt |
Power Supply | 100 -240 Volt |
Operating Humidity (RH) | 95 % |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
Standard Accessories Supplied With The Equipment | line cord, calibration certificate, Quick Start User Manual, CD-ROM with user manual (English),Programmers Guide. |
Dimensions (H X W X L) | 90x210x395 mm x mm x |
Weight | 3.5 Kg |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)/EL(C)/2013/0049A |
Test Report Date | 18.02.2013 |
Name Of The Lab | National Test House (SR) Chennai. |
Warranty | 3 Year |