Keysight 53220A Frequency Counter is a three-channel frequency counter with the ability to make all the frequency and time interval measurements you depend on. Standard two channels are to measure upto 350MHz and Third channel can be added to measure 6 or 15 GHz. 12 digits/second resolution, 100 psec time interval resolution. LXI-C/LAN, USB, GPIB. Built-in math analysis and color, graphical display trend and histogram. Offered configuration is Keysight 53220A with option 106 - Frequency Range upto 6 GHz and 010 - Ultra High Stability Time Base. Standard 3 Year warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. Delivery period 60 days..
Other Specifications Download Specification | |
---|---|
Frequency Range | 2 mHz to 3 GHz |
No. Of Channels | 2 No. |
Input Connector | BNC & N connector |
Type Of Input Signal | Burst, AM, FM and Noise Signal etc. |
Resolution | 10 or better Digit |
Input Impedance | 1 Mega Ohm |
Trigger Slope | Positive |
Display Type | Backlit (LCD Graphics Screen for Menu Control, Numerical Read Output & Status Information. |
Measurement | Frequency Period, Time, Phase, Volt,Duty Cycle, Pulse, Rise Time |
Indication | Frequency Level Status Indication (Bar Graph, Histogram) |
No. Of Digits | Programmable |
Time Base Type | OCXO |
Gate Time | 20 ns to 1000 s |
Single Shot Time Resolution | 100 Pico Sec |
Calibration | Electronic |
Aging Rate Per Year (AS Declared By The OEM) | 2 PPM |
Temperature Stability At 26 Degree C | 0.02 PPM |
Interface | GPIB & USB |
Operating Temperature | 0 C to +55 Degree C |
Storage Temperature | - 30 to +70 Degree C |
Short Warm Up Time | 45 Minutes |
Power Rating | 90 Watt |
Power Supply | 100 -240 Volt |
Operating Humidity (RH) | 5 to 80 Percent RH, non-condensing % |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
Standard Accessories Supplied With The Equipment | Offered Model Keysight 53220A with 106 is having frequency Range from 1mHz to 6 GHz with OCXO time base. Standard Accessories - CD containing Users guide, SCPI/programmers reference, programming examples, drivers (IVI-COM, LabView), IO library instructions, Power Line Chord, USB Cable |
Dimensions (H X W X L) | 261.1 mm W x 103.8 mm H x 303.2 mm D mm x mm x |
Weight | 3.9 Kg |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)EL(C)/2013/048B |
Test Report Date | 18/02/2013 |
Name Of The Lab | National Test House, Taramani, Chennai |
Warranty | 3 Year |