The Keysight U1252B 4.5-digit handheld digital Multimeter is feature-packed to simplify the troubleshooting of electronics and electrical circuits on the bench or in the field. Key capabilities include manual and automated data logging to both DMM and PC. For those long, continuous measurements, the DMM equips you with the easy-to-use GUI data-logging software to automate virtually unlimited data recordings to PC by using U1173B IR to USB Cable. The U1252B comes with 50,000 count dual display, 0.025 basic DC voltage accuracy, True RMS AC measurement, an integrated 20 MHz frequency counter for high frequency measurements, and a built-in programmable square-wave generator with selectable frequency and duty cycle. With the versatile U1252B, you are well equipped to perform thorough troubleshooting of any faulty circuit. Standard 3 year warranty. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent. STANDARD DELIVERY IS 6 WEEKS..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 4.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.1 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 200 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -20 Degree C to +55 Degree C |
Operating Humidity (RH) | 90 Percent RH |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 9V alkaline battery (ANSI/NEDA 1604A or IEC 6LR61) or 9V carbon-zinc battery (ANSI/NEDA 1604D or IEC6F22) or 7.2V or 8.4V Ni-MH rechargeable battery |
Total Voltage Of Battery | 9V |
Standard Accessories Supplied With The Equipment | Aligator clips, test probe lead(4-mm), Rechargeable Ni-MH battery with power adapter, U1173B IR to USB cable, certificate of calibration, quick start guide, Temperature Probe. Keysight Technologies has presence in India and have NABL Accredited Service and Calibration Lab in Bangalore & Delhi |
Dimensions (H X W X L) | 203.5 mm x 94.4 mm x 59.0 mm mm x mm x |
Weight | 527 g with Battery gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)EL( C)/2013/048J |
Test Report Date | 18/02/2013 |
Name Of The Lab | National Test House, Taramani, Chennai |
Warranty | 3 Year |