× All the transactions performed on 2.0 is available here. To access Market click "Home".

oscilloscope (jlab)(OSC01)

` 32,400.00

  • MRP: `36000.00

Analog Oscilloscope 20 MHz, 2 Channel..

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 1
  • Operating System - Windows
  • Bandwidth Upgradability - No
  • No. of Analog Channels - 2 Number
  • No. of Digital Channels - NA Number
  • Min. Detectable Pulse Width - NA ns
Other Specifications Download Specification
Type Digital
Operating System Windows
Bandwidth Upgradability No
No. Of Analog Channels 2 Number
Digital Channels No
No. Of Digital Channels NA Number
Record Length Per Digital Channel Simultaneously NA GS/sec
Sampling Rate Per Digital Channel Simultaneously NA Mega Points
Min. Detectable Pulse Width NA ns
Memory Upgradability No
Segmented Memory Feature Availability No
Vertical Sensitivity 2mV/Div to 5 V/Div
Vertical Resolution 8 bits
Coupling AC, DC, Ground
Time Base Range 2.5ns to 50 sec / division
Trigger Types 06
Measurements 32
Frequency Analysis Feature Yes
In-built Frequency Counter Yes
In-built Function Generator No
Acquisition Modes 03
Display Type Colour
Display Size 17.78CM TFT LCD CM CM
I/O Interface 03
Standard Accessories To Be Supplied Two 1X/10X switchable probes, Power Cord, Manual, Calibration Certificate.
Operating Temperature Range 10 to 40 degree C Degree C
Operating Humidity (RH) 80 RH at 30 degree C %
Power Supply 230V +- 10 , 50Hz
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration yes
Test Report No. JLAB/2017/101
Test Report Date 07/11/2017
Name Of The Lab JAIN LABORATORY INSTRUMENTS PVT LTD AMBALA
Warranty 1 Year
Real Time Bandwidth 100 MHz
Record Length Per Analog Channel Simultaneously 2 Mega Point
Sample Rate Per Analog Channel Simultaneously 1 GS/sec
Waveform Update Rate 30000 Waveforms/
Time Base Accuracy 50 PPM

Price Dekho Price Dekho Price List in india