Double Beam OpticsLarge 5 Inch Graphical DisplayAuto Wavelength SettingOn-Screen Cuve Display ModesBasic, Wavelength Scan, Multi-Wavelength,Kinetics, Quantitative, DNA/Protein Wavelength Range 190 1100 nm Spectral Bandwidth1.0 nm Optical System Double Beam, Grating 1200 lines/mmWavelength Accuracy 0.3 nm Wavelength Reapatability 0.2 nm Scanning Speed HI, MED, LOW, MAX. 3000 nm/min Photometeric Accuracy 0.3 T or 0.002 A/h @ 1A Photometric Range 0 200 T, -0.3 to 3A, 0 9999 Conc.Stray Light 0.05 T @ 220, 340 nm Stability 0.001 A/h @ 500 nm Display 5 inches Graphic LCD 320 x 240 dots Baseline Flatness 0.001A/h 200 1000 nm Sample Compartment Standard 8 cell with automatic cell changer 10 mmpath-length, 50 100 mm path-length optional at extra cost Light Source Halogen and Deuterium lamps Pre-Aligned OutputUSB Port for PC connectivity, Parallel Port for Dot Matrix PrinterPower230 V 10 AC, 50 Hz Dimensions L x B x HInstrument 5.
Other Specifications Download Specification | |
---|---|
Spectrophotometer Type | Microprocessor Based |
Display | High Resolution Touch Screen LCD Colour Graphical display with Built-in-Windows PC |
Monochromator | Concave holographic grating with 1200 lines/mm |
Wavelength Range (user Selectable) | 340-960 nm |
Wavelength Resolution | 0.2 nm |
Wavelength Accuracy | +-1 nm |
Repeatability | +-1 nm |
Spectral Bandwidth | < 2 |
Type Of Detector | Photodiode |
Measuring Modes | Transmittance (T), Absorbance (ABS), Concentration (CONC) by K Factor and Multi standards. |
Operating Mode | Single wavelength: Measuring 1, ABS and CONC |
Light Source | Tungstan Halogen Lamp |
Power | 230 V +- 10 50Hz |
Standard Accessories To Be Supplied | 10 nm path length four (4 nos.) Cuvettes matched with 3 percent |
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " | yes |
Power Requirements | 230 V +- 10, 50 Hz |
Operating Temperature | 15 - 35 c Degree C |
Operating Humidity (RH) | 0 % |
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" | NA |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) | yes |
Test Report No. | 43574 |
Test Report Date | 12-06-2016 |
Name Of The Lab | esico |
Warranty | 3 Year |