Automatic rotor detection, check of presence of accessories and compatibility with maximum speed, Safety speed limiter function, Controlled by microprocessor, Backlit color LCD display with contemporary visualization of all parameters, Digital adjustment of acceleration and deceleration levels, Compact sizes to optimize the space in laboratory, Stainless steel internal bowl with optimal height for loading and unloading of samples, Imbalance detection system with automatic functioning stop to avoid accidents, Automatic locking system of the lid, Safety opening of the lid in case of power failure, Brushless motor maintenance free and no carbon deposits, Construction in accordance with European directives.
Other Specifications Download Specification | |
---|---|
Centrifuge Design | Bench Top |
Centrifuge Type | Mini centrifuge |
Speed Mode | Variable Speed |
Rotor Configuration | Swinging Bucket |
Interchangeable Rotors | YES |
Material Of Rotor | Aluminium |
Finish Of Rotor | Other |
Autoclavable Rotor At 121 Degree Celsius | YES |
Type Of Drive Motor | Brushless induction Motor |
Controler Type | Microprocessor Controlled |
Body Material | Metal Alloy |
Finish Of Body | Powder coated |
Base Material | Steel |
Lid Type | Opaque |
Lid Material | other |
Lid Lock Detector | YES |
Emergency Lid Lock Release | YES |
Automatic Braking | YES |
Number Of Sample Tubes Testable Simultaneously | 48 |
Volume Of The Tube Testable | 10 ml |
Maximum Speed | 4500 RPM |
Minimum Speed | 500 RPM |
Speed Increment Step, If Variable Speed | 10 RPM |
Speed Control Accuracy Of Set Speed (+/-) | 10 RPM |
Maximum Relative Centrifugal Force(RCF) | 3600 x g |
Calibration | Manual Calibration |
Temperature Control Method | Ventilated |
If Refrigerated, Refrigeration System Free From CFC/HCFC | N/A |
Temperature Setting Range(increment Step) | N/A Degree Celcius |
Temperature Control Accuracy Of Set Temperature(+/-) | 0 Degree Celcius |
Acceleration Time (full Speed) | 47 sec |
Deceleration Time( Full Stop) | 60 sec |
Number Of Acceleration/deceleration Profiles In-built | 3 |
Timer Provided | YES |
Timer Setting (Increment Step) | 0:30 to 99:50 mins (in step of 10 seconds) min |
Input Method/Interface | Digital Front panel With Glove mode |
Display Option/Output Read Out Option | Digital |
Type Of Data Logging Option | Yes |
Rotor Imbalance Detection | YES |
Auto Cutoff | YES |
Pulse Mode | NO |
Programmable | YES |
Number Of Storable Programmes,If Programmable | 1 |
Input Voltage With Phase | 230 V |
Power Consumption | 455 W |
Input Current | 2 A |
Noise Level (maximum) | 60 db |
Ambient Operating Temperature | 45 Degree Celcius |
IP Rating Or Ingress Protection Rating | 21 |
External Dimension: Height | 330 mm |
External Dimension: Width | 450 mm |
External Dimension: Depth | 590 mm |
Weight Including Default Rotor | 40 kg |
Accessories And Spares Included In Standard Pack | Spanner, Cord wire, Operating panel |
Additional Safety Features | N/A |
Free Service Available | NO |
Warranty On Rotor And Machine | 1 Years |
Supply Of Free Spare Parts Under Warranty | YES |
Annual Maintenance Contract(AMC) Available After Warranty | NO |
AMC Contract Period | N/A Years |
Product Code Available On Supplier Website | YES |
If Yes, Product Code | NEYA 8 |
Firm Certified To ISO9001:2008 Or Latest | YES |
Product Is CE Certified | YES |
If CE Certified, EN/IEC Directives | EN 61010-2-020, EN 61326 |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | N/A |
Test Report No. | N/A |
Test Report Date | N/A |
Name Of The Lab | N/A |
Address Of The Lab | N/A |
Number Of Free Services, If Provided | 0 |