× All the transactions performed on 2.0 is available here. To access Market click "Home".

Online UPS Rating 10KVA with 30 Minutes Backup with VRLA SMF Batteries -3 in-1 out (axis)(AXIS 10K/1-1/30)

` 125,000.00

  • MRP: `150000.00

DSP Based Digital Controlled, TRUE Sine Wave Double Conversion Online UPS, Input Current Harmonic Suppression, High Frequency PWM with IGBT, Wide Input Voltage Range, High Efficiency Design, Enhanced protection against surges and line disturbances. Three Phase INPUT / Single Phase OUTPUTUser -friendly digital LCD display, Cold start function, High crest factor circuit design.We assure, It is quality product. Confirms AS PER IS-16242Part 12014.

  • Availability: 6 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 8000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 10 KVA
Technology IGBT-PWM
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 8000 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 2.5 %
Overall Efficiency 91 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. AERF/MALB/2527A/2014
Type Test Certificate Date 28.1.2014
Name Of Lab AERF
Address Of Lab NOIDA
Supply & Commissioning yes
Warranty 1 Years

Price Dekho Price Dekho Price List in india