Fluke quality is always within your reach. Your job requires that you have a rugged, reliable and accurate digital multimeter. The Fluke 15B digital multimeter does all that and more. Easy to use with one hand, even with gloves on, the Fluke 15B offers everything you need..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | Average |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 300 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 2.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 °C to 40 °C |
Operating Humidity (RH) | ≤90 % |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | Two AA |
Total Voltage Of Battery | 1.5 Volts each |
Standard Accessories Supplied With The Equipment | Test leads with caps, 2 AA |
Dimensions (H X W X L) | 183 x 91 x 49.5 mm mm x mm x |
Weight | 455g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Statement of Calibrfation certificate |
Test Report Date | Statement of Calibrfation certificate |
Name Of The Lab | Statement of Calibrfation certificate |
Warranty | 1 Year |