RAW WATER PUMP PURPOSE TO FEED THE DUAL MEDIA FILTER AT PRESSURE MORE THE 2.0 BAR ,WHICH IS MINIMUM OPERATING PRESSURE FOR FILTER. SPECIFICATIONS HORIZONTAL CENTRIFUGAL ? POWER REQUIRED : 1.0 HP ? MAKE : USHA/ KIRLOSKAR /Lubi. ? QUANTITY : 1 NO 2 MEDIA FILTER PURPOSE TO REDUCE THE TOTAL SUSPENDED SOLIDS, DIRT, IRON AND REDUCE SILT DENSITY INDEX WHICH CAN FOUL THE MEMBRANES SPECIFICATIONS ? MAKE : PENTEIR ? MATERIAL OF CONSTRUCTION : FRP ? DIA & LENGTH : 13*54 ? TESTING PRESSURE : 10KG/CM2 ? OPENING : TOP ? QUANTITY : 1 NO ? MULTIPORT : VALVE TYPE ? SIZE : 1.0 – 1 INCHES ? MAXIMUM FLOW : 6000 LPH ? WORKING : DOWN FLOW ? MEDIA : GRAVEL, PEBBLES ,QUARTZ SAND ,ANTHRACITE ETC. 3 CARBON FILTER PURPOSE TO REDUCE THE TOTAL SUSPENDED SOLIDS, DIRT, IRON AND REDUCE SILT DENSITY INDEX WHICH CAN FOUL THE MEMBRANES SPECIFICATIONS ? MAKE : WAVE CYBER OR PENTEIR ? MATERIAL OF CONSTRUCTION : FRP ? DIA & LENGTH : 13*54 ? TESTING PRESSURE : 10KG/CM2 ? OPENING : TOP ? QUANTITY : 1 NO ? MULTIPORT : VALVE TYPE ? SIZE : 1.0 – 1. INCHES ? MAXIMUM FLOW : 6000 LPH ? WORKING : DOWN FLOW ? MEDIA : CARBON. 4 MICRON FILTER PURPOSE TO REMOVE THE FINE PARTICLES UP TO 0.5 MICRONS AND REDUCE SILT DENSITY INDEX LEVELS TO ACCEPTABLE LEVELS. SPECIFICATIONS CARTRIDGE FILTER & HOUSING HOUSING : BIG BLUE ? MAKE : IMPORTED ? MOC OF HOUSING : PP ? LENGTH : 20” ? DIAMETER : 2” ? QUANTITY : 2 NOS CARTRIDGE : ? MAKE AMETEK USA ? CARTRIDGE MOC : POLYPROPYLENE ? LENGTH : 20” ? MICRON RATING : 05 MICRON ? QUANTITY : 2 NOS 5 DOSING SYSTEM PURPOSE TO DOSE ANTISILICA CHEMICAL , TO PROTECT THE SCALING FORMATION ON R.O. MEMBRANES. SPECIFICATIONS ? MOC: PP ? CAPACITY : 6 LPH ? PRESSURE : 10 PSIG ? QTY : 1 NO ? MAKE : E DOZE /ASTER/ EQV. 6 HIGH PRESSURE PUMP PURPOSE TO FEED THE REVERSE OSMOSIS MEMBRANE AT PRESSURE MORE THAN THE OSMOTIC PRESSURE TAKING IN CONSIDERATION FLUX RATE, FLOW AND RECOVERY. SPECIFICATIONS ? MOC : STAINLESS STEEL ? TYPE : VERTICAL ? FLOW RATE : 2.0-3.0 M3 ? POWER REQUIRED : 2.2 KW ? MAKE : SUMO/CRI 7 RO MEMBRANE PURPOSE TO REMOVE THE MAJOR PART OF TDS UPTO 95-98 % BY REVERSE OSMOSIS MEMBRANES ARRANGED AND DESIGNED TO GIVE ADEQUATE FLOW AND RECOVERY . SPECIFICATIONS ? TYPE : SPIRAL WOUNDED ? DIA.& LENGTH : 80*40 ? NO MEMBRANE : 1 NOS ? RECOVERY : 10 – 12 % EACH ? MAKE OF MEMBRANE : TRISUP/ HYDRA./DOW ? SALT REJECTION : 95-98 8 RO PRESSURE TUBE PURPOSE TO PACK REVERSE OSMOSIS MEMBRANES AND OPERATE AT HIGH-PRESSURE UPTO 250 PSI. SPECIFICATIONS ? MOC : FRP ? PRESSURE VESSELS : 1 NOS ? NO OF MEMBRANE PER VESSEL : 1 NOS IN EACH ? MAKE : PENTEIR / ULTIMA / WAVE CYBER 9 ELECTRICAL PANEL PURPOSE A CONTROL PANEL IS PROVIDED AS A SAFETY MEASURE FOR THE PUMPS & OTHER ELECTRICAL ITEMS. SPECIFICATIONS ? COMPLETE STARTERS, OVERLOAD RELAYS , SINGLE PHASE PREVENTION FOR PUMP. ? VOLTMETER , AMMETER , MCB’S , INDICATING LIGHTS ? PUSH BUTTONS ? ROCKER SWITCHES FOR DOZERS ? INCOMERS, AUTO- MANUAL SWITCHES.
Other Specifications Download Specification | |
---|---|
Conformity To Indian Standrad For System | IS:14724( latest) |
Output Water Of RO System Conforming To Indian Standard | IS:10500( latest) |
Input Water TDS | 1000 mg/L |
Output Capacity | 500 L/Hrs |
Recovery At 27 °C | 25-35 % |
Thin-film Composite Membrane. | Yes |
Ultraviolet (UV) LAMP | Yes |
Ultraviolet (UV)LAMP Wattage | 24 |
Number Of Float Valves/sensors | 1 |
High Pressure Pump | Yes |
Raw Water/Chemical Raw Water/Chemical Cleaning PUMP: | Yes |
Pre Filter Vessels: | Yes |
Micron Filter: | Yes |
Membrane Housing: | Yes |
Auto Cut: | Yes |
No Of Candles | 1 Nos |
Installation Type | Table Top |
Warranty For Free Candle And Activated Carbon Replacement Twice A Year | 2 Years |
Warranty For Free Replacement Of Machine | 2 Years |
Antiscalant- Where Silica Is Up To 100 Ppm/where Mica Is Up To 100 Ppm | Yes |
Iron Removing Filter Max. 0.3 Ppm | Yes |
Chloride & Flouride Removal Pump | Yes |
Availability Of Type Test Reporst(Design Evalution Reports) As Per Cl. No.5.3,6.1,6.2.1,6.2.2.1,6.2.2.2,6.2.2.3,6.2.2.4 To IS:14724 And Cl. 4,table 1,2,3and 4 To IS 10500. | Yes |
Test Certificate No. | W(S)-NN16-17/4006 |
Test Report Date | 11.02.2017 |
Name Of Lab Where Test Conducted | ND International |
Address Of The Test Lab | 107B, Block-F, New Alipore, Kolkatta |