The Fluke 1507 Insulation Testers are compact, rugged, reliable, and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.Additional features, like the remote probe on these tools save both time and money when performing tests.The Fluke 1507 Insulation Testers are compact, rugged, reliable,and easy to use. With their multiple test voltages, they are ideal for many troubleshooting, commissioning, and preventative maintenance applications.Additional features, like the remote probe on these tools save both time and money when performing tests. PI/DAR tests with real-time trending identify problems faster Temperature Compensation to establish an accurate baseline Troubleshoot advanced problems, perform preventive and predictive maintenance tasks in real time, to identify insulation breakdown using only one simple-to-use tool..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | NA |
Software | Not Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | -20 °C to 55 °C Degree C |
Operating Humidity (RH) | 0 % to 95 % @ 10 °C to 30 °C (50 °F to 86 °F) 0 % to 75 % @ 30 °C to 40 °C (86 °F to 104 °F) 0 % to 40 % @ 40 °C to 55 °C (104 °F to 131 °F) % |
Power Requirements | Battery Operated |
Type Of Battery | Four AA batteries (NEDA 15A or IEC LR6) |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | accessories: TL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe |
Dimensions (H X W X L) | 5.0 cm H x 10.0 cm W x 20.3 cm L mm x mm x |
Weight | 550 g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | shall be issued at the time of purchase |
Test Report Date | shall be issued at the time of purchase |
Name Of The Lab | shall be issued at the time of purchase |
Warranty | 1 |