Support The Bakelite Or Aluminium Moulded Support Tights The Pipe On Each Side With Rod And Nuts. Tube/Pipe Pipes Are Made From Special Porcelain.Slides The Guide Rod Carrying Contact Black Is Tightened With Screws To The Projection Of The Supports. The Sliders Are Provided With Phosphorous-Bronze Contact. These Have Double Contact System And Move Smoothly On The Sliding Rod.Terminals Three Brass Terminals Are Provided. One Terminal Being Connected To The Sliding Contact And The Other Two Of The Ends Of Winding, Enabling The Unit To Be Used As Rheostat Or Potentiometer.Winding Wires The Layers Of Electrical Oxidized Eureka Wire Wound On An Insulating Heat Resistance Porcelain Pipe According To The Length Required.Description Total Resistance And Max. Current Capacity Is Marked On The Sliders..
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 0-50 Degree C |
Gperating Humidity (RH) | N/A % |
PC Interface | USB |
Dimensions | N/A mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | N/A |
Test Report Date | N/A |
Name Of The Lab | N/A |
Warranty | 1 Year |