× All the transactions performed on 2.0 is available here. To access Market click "Home".

microtek 1 kva online ups external Batteries (microtek)(Microtek Nm36em1kk11 without Batteries)

` 14,500.00

  • MRP: `16300.00

High frequency and double conversion online technologyHigh end Micro Controller BasedWide Input voltage rangeAdvanced PFC TechnologyAdvanced Battery ManagementAutomatic Battery Charging in UPS off modeShort Circuit and overload protectionEMI / RFI noise filterSNMP card slot optionalLCD/LED Display simultaneouslySpecially designed to suit Indian power and environment conditionsGenerator CompatibleIsolation Transformer OptionalOver Temperature Protection.Different output Voltage settings.Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.Static Bypass Enable or Disable.Outlets Programmable and non programmable.Protection from DC Fan failure.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 200 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 1 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 200 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 5 %
Overall Efficiency 91 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. namh 1398
Type Test Certificate Date 15 sep 2015
Name Of Lab mtl
Address Of Lab mohali, punjab
Supply & Commissioning yes
Warranty 1 Years

Price Dekho Price Dekho Price List in india