Discover your real signals and capture more of their details with the industrys highest waveform capture capability. Automate setup, acquisition and analysis of high-speed serial data signals with a toolset engineered to deliver faster design debug and compliance testing..
Other Specifications Download Specification | |
---|---|
Type | Analog |
Operating System | Windows |
Bandwidth Upgradability | Yes |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | Yes |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 10mV/Div to 500mV/Div |
Vertical Resolution | 8 bits |
Coupling | DC,GND |
Time Base Range | 20ps to 1000 sec per division |
Trigger Types | Edge, Glitch, Width, Glitch, Runt, Window, Timeout, Transition Time, Setup/Hold, Pattern, State |
Measurements | 53 Automatic Measurements which 8 can be displayed at any one time (Amplitude, Time, Combination, Histogram, Communication related), Time & Voltage Cursors, Math (Add, Subtract, Divide, Multiply, Integration, Differentiation), Frequency Domain functions, Algebraic Expressions |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | No |
In-built Function Generator | Yes |
Acquisition Modes | Sample, Peak Detect, Average, Envelope, Hi resolution, Waveform database, fast frame acquisition |
Display Type | Colour |
Display Size | 30.73 CM |
I/O Interface | USB,LAN, GPIB, LXI Class C |
Standard Accessories To Be Supplied | Power Cord, Keyboard,Mouse, Accessory Pouch,Front Cover,user manual, adapters, wrist strap |
Operating Temperature Range | 5 to +45 Degree C |
Operating Humidity (RH) | 8 to 80 % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | NTH(SR)/EL(C)/2013/325(H) |
Test Report Date | 07.10.2013 |
Name Of The Lab | NTH,Chennai |
Warranty | 3 Year |
Real Time Bandwidth | 4000 MHz |
Record Length Per Analog Channel Simultaneously | 31.25 Mega Point |
Sample Rate Per Analog Channel Simultaneously | 25 GS/sec |
Waveform Update Rate | 300000 Waveforms/ |
Time Base Accuracy | 1.5 PPM |