The Keysight U1251B 4.5-digit handheld digital multimeter DMM is feature-packed to simplify the troubleshooting of electronics and electrical circuits on the bench or in the field. Key capabilities include manual and automated data logging to both DMM and PC. For those long, continuous measurements, the DMM equips you with the easy-to-use GUI data-logging software to automate virtually unlimited data recordings to PC using U1173B. With the versatile U1251B, you are well equipped to perform thorough troubleshooting of any faulty circuit. U1251B has 50,000 count dual display, 0.03 basic DC voltage accuracy, True RMS AC measurement. The Instrument will be supplied with Aligator clips, test probe lead4-mm, Alkaline 9V Battery, certificate of calibration, test report, quick start guide. Standard 3 year warranty. The standard delivery period is 6 to 8 weeks. Refer Keysight datasheet for detailed specifications. Prices indicated including GST @18 percent.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 4.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | .05 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | .01 to 1000 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | –20 to 55 °C |
Operating Humidity (RH) | 80% RH for temperatures up to 35 °C |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | one number 9 V alkaline battery (ANSI/NEDA 1604A or IEC 6LR61) 9 V carbon-zinc battery (ANSI/NEDA 1604D or IEC6F22) 7.2 V or 8.4 V Ni-MH rechargeable battery |
Total Voltage Of Battery | 9V |
Standard Accessories Supplied With The Equipment | Aligator clips, test probe lead(4-mm), Alkaline 9V Battery, certificate of calibration, test report, quick start guide |
Dimensions (H X W X L) | 203.5 mm x 94.4 mm x 59.0 mm mm x mm x |
Weight | 504±5 g with battery gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Yes |
Test Report Date | Yes |
Name Of The Lab | Yes |
Warranty | 3 Year |