Keysights Truevolt 34461A digital multimeter DMM offer a full range of measurement capabilities and price points with higher levels of accuracy, speed, and resolution. Truevolt DMMs graphical capabilities such as trend and histogram charts offer more insights quickly. Also provide a data logging mode for easier trend analysis and a digitizing mode for capturing transients. The ability to measure very low current, 1 microA range with picoA resolution, allows you to make measurements on very low power devices. Color, graphical display with built-in bar chart, histogram, trend, math, and statistics. 12 measurement functions DC/AC voltage, DC/AC current, 2- and 4-wire resistance, Diode, Continuity, Frequency, Period, Temperature, capacitance. Basic accuracy 0.0035percent DC,0.06percentAC.1000 readings/second, 10000 reading memory. BenchVue enabled.Standard 3 year warranty.Refer Keysight datasheet for detailed specifications.Prices indicated including GST @18 percent.STANDARDDELIVERY6weeks.
Other Specifications Download Specification | |
---|---|
Type | Benchtop |
Display | 6.5 Digit |
Measurement Type | True RMS |
Count | 200000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 2000 points 500 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category II 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0 to 55 degree C |
Operating Humidity (RH) | Full accuracy to 80 percent R.H. at 40 degree C non–condensing |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | NA |
Total Voltage Of Battery | NA |
Standard Accessories Supplied With The Equipment | Power cord Calibration certificate, 34138A test lead set with probes, fine tip probes |
Dimensions (H X W X L) | 212.8 mm x 88.3 mm x 272.3 mm mm x mm x |
Weight | 3.76 kg (8.3 lb) gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | NTH(SR)EL(C)/2014/00202 |
Test Report Date | 20/05/2014 |
Name Of The Lab | NTH Taramani, Chennai |
Warranty | 3 Year |