With 2U performance packed into a compact 1U chassis, the PowerEdge R630 two-socket rack server delivers uncompromising density and productivity. Part of the 13th generation of PowerEdge servers, the R630 is ideal for virtualization, driving large business applications or running transactional databases.
Other Specifications Download Specification | |
---|---|
Processor Configuration | E5-2650 v4, 12 core, 2.20GHz with 30 MB smart cache memory, 105 watt |
Form Factor | Rack |
Processor Make | Intel |
Max. Number Of Sockets Available On Chipset | 2 |
Max. Number Of Sockets Populated With Processor | 2 |
No. Of Processor | 1 |
Number Of Core Per Processor | 12 |
Chipset Compatible With CPU | Intel C610 |
Motherboard (OEMcompatible With CPU) | Yes |
PCI Slots (Express Gen 3.0 Min.) | x3 |
Max Nos Of PCI Lanes | 32 |
Memory ( DDR4 RAM Min.) | 2x8GB RDIMM, 2400MT/s, Single Rank, x8 Data Width GB |
DDR4 RAM Upgradable Upto (Minimum) | 1.5TB GB |
DIMM Slots (Minumum) | 24 No. |
Hard Disk Drive Capacity | 3x600GB 10K RPM SAS 2.5in Hot-plug Hard Drive GB |
Hard Disk Drive RPM With SAS (hot Plug Or Better ) | 10K RPM RPM |
RAID Controller Caches | 1GB MB |
RAID Controller | PERC H730 Integrated RAID Controller, 1GB Cache |
RAID Controller Ports | 2 |
Video Controller (support VGA Or Above Resolution) | Yes |
Keyboard | standard |
Mouse | Optical scroll |
Bays (min. 2 Internal Or More Hot Plug) | 8 |
USB Ports (version 2.0/3.0) | 4 |
Certifications, Compliance & Support By Windows, Red Hat Or Novell. | Yes |
DVD ROM (or Better) | 8x or better |
Networking: Dual LAN (10/100/1000) Network Card With Asset Feature Tracking & Security Management, Remote Wake Up | Yes |
FC HBA Dual Port Card | Available |
FC HBA Dual Port Card Speed | NA |
Power Management | Screen blanking, hard disk & system idle mode in power on, set up password, power supply surge protected |
Redundant Power Supply | Yes |
Redundant Fan | Yes |
Server Scalability To Be Achived Within The Box & Without Adding Nodes | Yes |
Avaialbiklity Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A. Dry Heat Test (For 16 Hrs At A Temp. Of 45 Degree C In Accordance With IS: 9000/part-3/section-5/1977). B. Cold Test(For 4 Hrs At A Temp. Of 0 Degree C In Accordance With IS: 9000/part-2/section-4/1977. C. Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 40 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981) Note:- The Server Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, The Server Shall Be Functional. | Yes |
Availability Of The Type Test Report From Central Govt./ NABL/ ILAC Acredited Lab. Covering Verification Of All Features & Functional Parameters & Environmental Tests Sequence. | Yes |
Test Report No. & Date | NA |
Name & Address Of Lab | NA |
BIS Registration No. Under CRS Of Deity | NA |
Declare SPEC Int_rate_base 2006 & Specfp_rate_2006 For 1,2,4,8 Prcessor As Applicable. | NA |
Declare Max. Power Consumption Of The System | NA |
Availability Of Documentary Evidence In Support Of Model Quoted In Commersial Production & Due Evaluation Completed | Yes |
Details Of Benchmark Indices With Software & Diagnostic Software Used To Test Server. | NA |
Server Main Supply | 230V, ±10%,50 Hz |
CE Or UL Certified Or Ertl/Etdc Certified For Safety (IEC-60950-1) | Yes |
RoHS Compliance | Yes |
Warranty | 1 years |