GREEN-WATT High Voltage Insulation Tester GW-5KP embedded real-time industrial microcomputer operating system, ultra-thin wire shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level 500V,1000V,2500V,5000V, high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation,automatic calculation of various insulation index absorption ratio, polarization index, all measured characteristics with the anti-power-down function .It is suitable for measuring high capacity transformers, transformers, generators, high voltage electric motors, power capacitors, power cables,surge arresters and other ideal insulation resistance test equipment..
Other Specifications Download Specification | |
---|---|
Type | Portable |
Measurement Range | 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm |
Test Voltage | 50, 100, 250, 500 and 1000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | more than 99 locations |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | 0-40 Degree C Degree C |
Operating Humidity (RH) | 85% OR LESS % % |
Power Requirements | Battery Operated |
Type Of Battery | Lead-acid Battery |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Line probe, Earth cord, Guard cord, Hook type, Power adaptor, Hard case, Instruction manual |
Dimensions (H X W X L) | 130X225X208 mm x mm x |
Weight | 4000 gms gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | na |
Test Report Date | na |
Name Of The Lab | na |
Warranty | 1 |