× All the transactions performed on 2.0 is available here. To access Market click "Home".

online ups 5 kva with batteries (apc)(5kUXI)

` 215,000.00

  • MRP: `239000.00

5 KVA ONLINE UPS APC WITH 16NOS 42AH EXIDE/ROCKET BATTERIES FOR 60 MIN BACKUP WITH BATTERY RACK.WARRANTY ON BATTERY 1 YEAR ONLY. 94 efficiency Double-conversionSave Rs 10k every yearSave even more in Green mode,98 efficiency0.9 power factor 4.5kW output for5kVA, 5.4kW for 6kVASeparate Bypass input for Hotstandby redundancyAPC Online 5k / 6kVASRC5KUXI, SRC6KUXIIntroducing state of the art, Next Gen Online UPS123standby redundancyStatic Bypass switch for smoothtransferHigh-Power Charger 1500W maxSMF / Flooded battery selectableGenset-compatibleGraphical LCD easy-to-use interfaceSmartSlot for all management cardoptionsEPO, USB, RS232C, Dry ContactsRack/Tower convertible, 3U in rackParalleling option coming soon.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 8000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 5 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 60 Minutes
Minimum VAH 8000 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 2 %
Overall Efficiency 98 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NA
Type Test Certificate Date NA
Name Of Lab NA
Address Of Lab NA
Supply & Commissioning YES
Warranty 3 Years

Price Dekho Price Dekho Price List in india