Fluke 114 Electrical True-RMS digital multimeter with a 03 years warranty. Its AutoVolt capability automatically switches to measure AC or DC voltage. The LoZ function helps identify so-called ghost voltage and prevent false readings. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes easy. Tested for safe use in CAT III 600V environments. AutoVolt automatic ac/dc voltage selection.Large white LED backlight to work in poorly lit areas. Resistance and continuity. Min/Max/Average to record signal fluctuations. CAT III 600 V safety rated.All inputs are protected to CE, IEN61010-1 CAT III 600V.AC Voltage Measurement Accuracy-1.0 percent plus 3. AC Current MeasurementAmpere-NO. AC Current Measurement Accuracy-NO. DC Current MeasurementAmpere-NO. DC Current Measurement Accuracy-NO. Frequency Measurement Kilo Hertz-NO. Frequency Measurement Accuracy-NO. Feature Of Data Logging-NO. True RMS AC Voltage Band Width is DC To 1KHz..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 6000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 3 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 3 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 50 Kilo Hertz |
Frequency Measurement Accuracy | 100 % |
Capacitance Mreasurement Range | NA Micro Fara |
Capacitance Measurement Accuracy | NA % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Not Available |
If Data Logging Feature Is Available, Internal Memory | NA |
Computer Interface Alongwith Software | Not Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | -10 °C to 50 °C |
Operating Humidity (RH) | 90% |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 9V Alkaline |
Total Voltage Of Battery | 9V |
Standard Accessories Supplied With The Equipment | Model includes the following: Holster Installed 9 V battery Test leads User manual |
Dimensions (H X W X L) | 167.1 mm X 85.1 mm X 46.0 mm mm x mm x |
Weight | 550g gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Statement of calibartion practises and CSA test certificates are provided |
Test Report Date | Statement of calibartion practises and CSA test certificates are provided |
Name Of The Lab | Statement of calibartion practises and CSA test certificates are provided |
Warranty | 3 Year |