× All the transactions performed on 2.0 is available here. To access Market click "Home".

BPE Online ups 30 KVA epplus 30KVA (BPE)(epplus 30KVA 60 minutes backup 48000VAH with 3 year warranty)

` 750,000.00

  • MRP: `899000.00

Features 1.Online double conversion.2.DSP technology guarantees high reliability.3.True galvanic isolation transformer design withstand all kinds of loads.4.Management to prolong battery life cycle.5.Fan design and independent ventilation enhance durable operation under harsh environment. 6.Adjustable battery numbers.7.Accept dual-mains input.8.Parallel operation with up to 4 units option.9.Variety of communication options available .10.SNMP, Rs485, Modbus compatability..

  • Availability: 300 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - Three phase 300 V - 450V sinewave,50Hz
  • Output power - 3 phase 400 V ±1% with alternative user setable setting of 380V+-1%,50Hz
  • Minimum VAH - 48000 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 30 KVA
Technology IGBT-PWM
Input Power Three phase 300 V - 450V sinewave,50Hz
Output Power 3 phase 400 V ±1% with alternative user setable setting of 380V+-1%,50Hz
Backup Time 60 Minutes
Minimum VAH 48000 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. Will be available to Buyer on demand
Type Test Certificate Date Will be available to Buyer on demand
Name Of Lab ETDC
Address Of Lab Bangalore
Supply & Commissioning FREE SUPPLY & INSTALLATION
Warranty 3 Years

Price Dekho Price Dekho Price List in india