Hard waterWhen water is referred to as hard this simply means, that it contains more minerals than ordinary water. These are especially the minerals calcium and magnesium. The degree of hardness of the water increases, when more calcium and magnesium dissolves.Magnesium and calcium are positively charged ions. Because of their presence, other positively charged ions will dissolve less easily in hard water than in water that does not contain calcium and magnesium.This is the cause of the fact that soap doesnt really dissolve in hard water.1.2 Which industries attach value to hardness of waterIn many industrial applications, such as the drinking water preparation, in breweries and in sodas, but also for cooling- and boiler feed water the hardness of the water is very important. Water softeningWhen water contains a significant amount of calcium and magnesium, it is called hard water. Hard water is known to clog pipes and to complicate soap and detergent dissolving in water.Wat.
Other Specifications Download Specification | |
---|---|
Iron Removal Unit | With |
Prefilter Provided With Flushing Valve In The Iron Removal Unit | YES |
Iron Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Discharge Capacity Of The Iron Removal Equipment | 1000 LPH |
Material Of Body Of Iron Removal Equipment | FRP |
Diameter Of Vessel Of Iron Removal Equipment | 300mm mm |
Height Of Vessel Of Iron Removal Equipment | 1200mm mm |
Number Of Iron Removal Vessel | 1 Nos |
Minimum Thickness Of Vessel Of Iron Removal Equipment | 6mm mm |
Material Of Strainer Plate Of Iron Removal Equipment | PP |
Diameter Of Strainer Plate Of Iron Removal Equipment | 65mm mm |
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment | 2mm mm |
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment | 24 Nos |
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment | 24 Nos |
Material Of Strainer In Strainer Plate Of Iron Removal Equipment | PP |
Quantity Of Iron Removal Media In Iron Removal Vessel | 50 ltrs Kg |
Quantity Of Filter Media In Iron Removal Media | 60 kgs Kg |
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel | 40% |
Back Wash Valve In Iron Removal Vessel | NA |
The Accumulated Ferric Is Removed From The Media While Back Washing | YES |
Maximum Iron Content Of Inlet Water | 10ppm ppm |
Maximum Iron Content Of Outlet Water | 0.3 ppm |
Process By Which Iron Is Removed From Water By Iron Removal Media | desolved |
Life Of Iron Removal Media | 3 Years |
Cost Of Refilling Of Iron Removal Media | 10000 Rupees |
Life Of Iron Removal Unit | 5 Years |
Protective Coating Of Iron Removal Vessel | Epoxy |
Inlet Pipe Size Of Iron Removal Unit | 20 mm |
Space Required For Installation Of Iron Removal Unit | 10X10 Square Metres |
Number Of Valves In Iron Removal Unit | 5 Nos |
Materal Of Valve Of Iron Removal Unit | U PVC |
Diameter Of The Valve In Iron Removal Unit | 20 Nb mm |
Pressure Gauge In Iron Removal Unit | YES |
Pressure Release Valve In Iron Removal Unit | YES |
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit | 1.5 kg Kg/square cm |
Weight Of Iron Removal Unit | 150 Kg |
Warranty Period Of Iron Removal Unit | 2 Years |
Arsenic Removal Unit | Without |
Discharge Capacity Of The Arsenic Removal Unit | 1000 LPH |
Arsenic Removal Unit Suitable For Water Supply Equipment | Hand Pump |
Material Of Arsenic Removal Vessel | FRP |
Diameter Of Arsenic Removal Vessel | 300 mm |
Height Of Arsenic Removal Vessel | 1100 mm |
Minimum Thickness Of Arsenic Removal Vessel | 6mm mm |
Number Of Arsenic Removal Vessel | 1 Nos |
Material Of Strainer Plate Of Arsenic Removal Vessel | PP |
Diameter Of Strainer Plate Of Arsenic Removal Vessel | 65mm mm |
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel | 2mm mm |
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate | 2mm Nos |
Material Of Strainer In Arsenic Removal Strainer Plate | PP |
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel | 50 kg Kg |
Media Used For Removal Of Arsenic From Water | 69 kg |
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel | 40% |
Maximum Arsenic Content Of Inlet Water | 10 ppm |
Maximum Arsenic Content Of Outlet Water | 0.01 ppm |
Life Of Arsenic Removal Media | 3 Years |
Cost Of Refilling Of Arsenic Removal Media | 20000 Rupees |
Life Of Arsenic Removal Unit | 5 Years |
Protective Coating Of Arsenic Removal Vessel | Epoxy |
Inlet Pipe Size Of Arsenic Removal Unit | 20 mm |
Space Required For Installation Of Arsenic Removal Unit | 10x10 Square Metres |
Number Of Valves In Arsenic Removal Unit | 5 Nos |
Materal Of Valve In Arsenic Removal Unit | U PVC |
Diameter Of The Valve Of Arsenic Removal Unit | 300 mm |
Pressure Gauge In Arsenic Removal Unit | YES |
Pressure Release Valve In Arsenic Removal Unit | YES |
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit | 1.5 kg Kg/square cm |
Weight Of Arsenic Removal Unit | 150 kg Kg |
Warranty Period Of Arsenic Removal Unit | 2 Years |
Iron Removal Media Conform To International Standard | National Science Foundation, USA |
Arsenic Removal Media Conform To International Standard | National Science Foundation, USA |
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate | YES |
Field Testing Kit For Testing Iron & Arsenic Is Provided | YES |