× All the transactions performed on 2.0 is available here. To access Market click "Home".

online ups 90 min back up (luminous)(ld6000 - luminous 6kva ups)

` 49,798.00

  • MRP: `59000.00

I/P -Single Phase 110V-300 V sinewave 50/60 HZ,O/P - Single Phase 230V 1 sinewave 50Hz, BKUP TIME- 90 Mins-12 V, 75 ah x 16, VOLT REGULATION FROM NO LOAD TO FULL LOAD in prct -230V /- 1 static regulation,INBUILT ISOLATION TRSFMR - No,130 prct OVERLOAD LIMIT FOR MIN 1 Mnts -Yes,110 prct OVERLOAD LIMIT FOR MIN 10 Mnts - yes,TOTAL HARMONIC DISTORTION in prct - 3 on Linear Load, OVERALL EFFY - 92 prct,TYPE OF BATT - SMF-VRLA conforming to JISC87029Pt.I,II III, MIN THICKNESS OF M.S.SHEET ENCLOSURE -0.9 MM, DEG OF PROTECTION - ip20, PROTECTION OF OVER VOLT,SHORT CIRCUIT OVER LOAD AT UPS O/P TERMINALYes,PROTECTION FOR UNDER VOLT AT BATT TERMINAL AT 10.5V PER 12 V BATT yes, MAX OVERSHOOT AND UNDER SHOOT OF O/P RATED VOLT NA,INDICATORS FOR MAINS PRESENCE,BATT CHARGING DISCHARGING,O/P OVER LOAD, LOW BATT VOLT Yes, DIGITAL METERING IN UPS FOR AC I/P VOLT,O/P AC VOLT, CURR FREQY,BATT VOLT CURR Yes.

  • Availability: 8 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - MOSFET-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 14400 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 6 KVA
Technology MOSFET-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 90 Minutes
Minimum VAH 14400 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 2 %
Overall Efficiency 92 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NTS/PPTL/UPS-309/04
Type Test Certificate Date 9-Oct-15
Name Of Lab Nisaki Technology Services
Address Of Lab No. 46, Park Road, 2nd Main, 10th Cross, Wilson Garden, Bangalore - 27
Supply & Commissioning Yes
Warranty 2 Years

Price Dekho Price Dekho Price List in india