× All the transactions performed on 2.0 is available here. To access Market click "Home".

microtek supermax series online ups 5kva 180V with 90 minute Backup (microtek supermax series online ups 5kva 7560 vah)(microtek supermax series online ups 5kva 7560 vah)

` 156,530.00

  • MRP: `177875.00

Microtek Online UPS provides Uninterrupted Pure Power for Critical Applications such as Computer Network, Servers, Cyber Cafes, ATM Machine, Labs etc. .Rated capacity 5kva 7560 VAH WITH Battery Rack and 15 FIFTEEN 42AH BATTERIES OF EXIDE MODEL EP42-12.

  • Availability: 5 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 7560 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 5 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 90 Minutes
Minimum VAH 7560 VAH
Voltage Regulation From No Load To Full Load 0.5 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) .6 %
Overall Efficiency 97 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries With
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. AS PER OEM
Type Test Certificate Date AS PER OEM
Name Of Lab AS PER OEM
Address Of Lab AS PER OEM
Supply & Commissioning YES.
Warranty 2 Years

Price Dekho Price Dekho Price List in india