true-on-line ups systems intelligent ups, using igbt dsp technology galvanic isolation transformer (bl electronics)(bl-3k-168v)

` 47,731.86

  • Offered Price: ` 48214.00
  • MRP: `53572.00

Microcomputer-Chip basedHigh Frequency Design ensures Low Switching Losses Purity of Sine-Wave Ultra-fast Transient Response Very Low Noise IGBT in Charger section Earthing Protection Double Convertion INPUT 155V 280 V AC Single phase 45 60 Hz. 230VAC 1.0 Single Phase 50 Hz 0.1 Crystal Controlled 3.0 KVA ,0.8 lagging to unity,For 100 step load change output stays within 5 and recovers within cycle,On-board Panel Meter to display following parameters Output Voltage Input load status Battery status bar Load status bar, Battery Status Bar, Fault Diagnostic on LCD Panel Input output Frequency Online Battery Test Pure Sine Wave,Total Harmonic Distortion less than 2 for linear load.Total Harmonic Distortion less than 5 for non-linear load 100 Continuous 150 for 30 seconds 0 to 50C. 95 R.H. MaximumOur UPS has passed Environmental Test From DefenceLa.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 10
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 2016 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 3 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 2016 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) Total Harmonic Distortion less than 2% for linear load. • Total Harmonic Distortion less than 5% for non-linear load %
Overall Efficiency 90 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. MUM-0001777
Type Test Certificate Date 02/01/2017
Name Of Lab NSIC
Address Of Lab MUMBAI
Supply & Commissioning 40
Warranty 1 Years