Multi Series Digital multimeter.
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | Average |
Count | 4000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.5 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 1.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 1 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 1 % |
Frequency Measurement | 100 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | NA Degree C |
Temperature Measurement Accuracy | NA % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | NA |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | -10 to +50 |
Operating Humidity (RH) | 75% |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | UL |
If Battery Operated, Type And No. Of Battery | 6 X 1.5V |
Total Voltage Of Battery | 9V |
Standard Accessories Supplied With The Equipment | 1 Digital Meter, 1 Probe Set, 1 Protective case, 1 User Manual, 1 Test Certificate,1 set extra fuse |
Dimensions (H X W X L) | 195 X 84 X 35 mm x mm x |
Weight | 350 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | 344 |
Test Report Date | 13/09/2016 |
Name Of The Lab | NABL Approved |
Warranty | 3 Year |