GW INSTEK PSM 3004 single output / dual range, 120 or 200W, programmable linear DC power supplies. OVP, OCP, OTP, and, output On/Off control protect the PSM-Series and their load from unexpected conditions. High resolution, high regulation, and low ripple are maintained at 1mV/1mA, 0.01, and 350 Vrms, respectively. Operation and configuration is simplified with a digital interface and a clear LCD display. Standard features include store/recall output memories, automatic stepping with timers for continuous testing and self-testing, and software calibration features to reduce maintenance efforts. SCPI programming, LabVIEW drivers, RS-232C, and GPIB interfaces enable easy automated test system integration and remote control. The PSM-Series are an ideal choice for high precision applications such as QA verification and product development. The Price includes GST at the rate 18 Present.
Other Specifications Download Specification | |
---|---|
DC Voltage Output Rating | 0 to 30 Volt |
DC Current Output Rating | 0 to 4 Ampere |
Maximum Power | 120 Watt |
Load Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 2 mV |
Load Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 1.5 mA |
Line Regulation (Voltage) ± (% Of Output + Offset) | less than 0.01 + 1 mV |
Line Regulation (Current) ± (% Of Output + Offset) | less than 0.05 + 0.1 mA |
Over Voltage Protection Accuracy | +- 0.5 + 0.5 V |
Over Voltage Protection Response Time | less than 10 milli sec |
Ripple And Noise Voltage (20 Hz To 20 MHz) | less than 1 mVrms less than 4 mVpp |
Ripple And Noise Current (20 Hz To 20 MHz) | less than 4 mArms |
Readback Voltage Accuracy | 0.05 + 10 mV |
Readback Current Accuracy | 0.15 + 4 mA |
Readback Voltage Resolution | 1 mV |
Readback Current Resolution | 0.1 mA |
Operating Temperature | 0°C to 50°C Degree C |
Gperating Humidity (RH) | ≤80% % |
PC Interface | USB |
Dimensions | 230X140X380 mm x mm x |
Weight | GPIB gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | PMR |
Test Report Date | 02/08/2017 |
Name Of The Lab | OEM Calibration |
Warranty | 3 Year |