× All the transactions performed on 2.0 is available here. To access Market click "Home".

fluke-107, digital multimeter (fluke)(fluke-107)

` 5,400.00

  • MRP: `6500.00

Palm sized multimeter with AC/DC current, Backlight and SMART strap,Voltage measurement - 600V AC/DC, CAT-III 600V safety rating,With AC/DC Current, mV AC, Resistance and Capacitance measurement,Data hold, Continuty test, Diode Test, Duty cycle and long battery life,Supplied with TL75 test leads, Smart Strap, Statement of Calibration, 1 Year warranty.

  • Availability: 49 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - Average
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.5 %
  • AC Current Measurement - 10 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type Average
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.5 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.5 %
AC Current Measurement 10 Ampere
AC Current Measurement Accuracy 1.5 %
DC Current Measurement 10 Ampere
DC Current Measurement Accuracy 1.5 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 1.5 %
Frequency Measurement 100 Kilo Hertz
Frequency Measurement Accuracy 0.1 %
Capacitance Mreasurement Range .01 to 1000 Micro Fara
Capacitance Measurement Accuracy 2.5 %
Temperature Measurement NA Degree C
Temperature Measurement Accuracy NA %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Not Available
If Data Logging Feature Is Available, Internal Memory NA
Computer Interface Alongwith Software Not Available
True RMS AC Voltage Band Width NA
Safety Rating Category III 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range 0-40 degree C
Operating Humidity (RH) Non-condensing when
Power Requirements Battery Operated
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 02 nos. AAA Battery
Total Voltage Of Battery 3 VOLT
Standard Accessories Supplied With The Equipment • Fluke 107 Palm-sized Digital Multimeter with Frequency, Diode Test , Tl75 Hard Poin Test Lead Set , 2 AAA Batteries (Installed) , User's Manual ,Smart Strap
Dimensions (H X W X L) 142X69X28 mm x mm x
Weight 200 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. Statement of Calibration Pracitices(SOC)
Test Report Date Statement of Calibration Pracitices(SOC)
Name Of The Lab Standard
Warranty 1 Year

Price Dekho Price Dekho Price List in india