× All the transactions performed on 2.0 is available here. To access Market click "Home".

microtek 2 kva online ups with internal battery (microtek)(2 kva ib)

` 38,500.00

  • MRP: `51975.00

Capacity2KVA / 1600WInputVoltage RangeWhen load 50, range is 1185VAC2955VACWhen 50 load, input range is 1605VAC2955VACFrequency4654Hz0.5HzPhaseSingle PhaseInput Power Factor 0.95OutputVoltage208/220/230/240V ACFrequency Range50Hz 0.2THD Liner Load3THD Non-Liner Load5Overload Capability110 30s turn to bypass mode150, 200ms turn to bypassCrest Factor31 maxShot Circuit Protection5 cycles turn off inverter, no transfer to bypass, provide alarm AC mode, 5 cycles turn off inverter, provide alarm battery mode, input fuse blown or breaker actionWaveformPure Sine WaveTransfer time AC to bypass mode4ms typical 2.5msEfficiency8592BatteryDC Voltage72VDC -inbuilt battery 7ah x 6 nos Charge Current0.7A 08ACommunication InterfaceRS232 SNMP Optiona lLED / LCD Indication LCD Indications Noise Level45dB / Net Wt. Product Kg.421190.

  • Availability: 20 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 432 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 2 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 30 Minutes
Minimum VAH 432 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 4 %
Overall Efficiency 92 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NA
Type Test Certificate Date NA
Name Of Lab NA
Address Of Lab NA
Supply & Commissioning NA
Warranty 1 Years

Price Dekho Price Dekho Price List in india