microtek 5 kva online ups with 60 minuts backup (microtek)(microtek 5 kva with 60 minuts abckupr)

` 109,012.50

  • Offered Price: ` 114750.00
  • MRP: `127500.00

Technical Specifications- Microtek 5-Kva online SuperMax series 1 single PhaseModelSupermax-Series - ICapacity5KVA TechnologyDouble Conversion high Freq. Switching PWM, using IGBTsInputVoltage Range160V AC270V AC 5V AC, Single Phase for upto 10KVA and 360V AC450V AC 5V AC, Three Phase for upto 30KVAFrequency4555HzPhaseSingle phase upto 10KVA and Three Phase from 5 to 30KVAGenerator CompatibilityPresentOutputVoltage230V Ac 1Frequency Range50Hz 0.5THD Liner Load3THD Non-Liner Load5Overload Capability125 for 2minuted / 150 for 30SecondsCrest Factor31 maxShot Circuit ProtectionInstantWaveformPure Sine WaveManual BypassInbuilt upto 15KVAStatic Bypass optional5msInverter Efficiency 90 on rated full loadOverall Efficiency 80BatteryDC Voltage180 vdcMimic Control PanelLED for UPS status and LCD for Voltage, Current FrequencyAudible AlarmFor Battery Low / DC High / Output.

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Technology - IGBT-PWM
  • Input Power - single phase 160V - 260V sinewave,50Hz
  • Output power - single phase 230V ±1% sinewave,50Hz
  • Minimum VAH - 1080 VAH
  • 20% Overload limit for minimum 10 minutes - Yes
Other Specifications Download Specification
Rating In KVA 5 KVA
Technology IGBT-PWM
Input Power single phase 160V - 260V sinewave,50Hz
Output Power single phase 230V ±1% sinewave,50Hz
Backup Time 60 Minutes
Minimum VAH 1080 VAH
Voltage Regulation From No Load To Full Load 1 %
Inbuilt Isolation Transformer Yes
20% Overload Limit For Minimum 10 Minutes Yes
50% Overload Limit For Minimum 1 Minutes Yes
Total Harmonic Distortion(THD) 3 %
Overall Efficiency 93 %
Type Of Battery SMF-VRLA conforming to JISC:8702(Pt.I,II&III)
Minimum Thickness Of M.S.Sheet Enclosure Duly Painted 1.2 mm
Degree Of Protection IP21
Protection Of Over Voltage,Short Circuit & Over Load At UPS Output Terminal Yes
Protection For Under Voltage At Battery Terminal At 10.5V Per 12 V Battery. Yes
Maximum Overshoot And Under Shoot Of Output Rated Voltage 4
Indicators For Mains Presence,Battery Charging And Discharging,Output Over Load, Low Battery Voltage Yes
Digital Metering In UPS For AC Input Voltage,Output AC Voltage,Current,Frequency,Battery Voltage And Current Yes
Movable Trolly For Batteries Without
Dry Heat Test : In Accordance With IS:9000 (part 3/sec.5)1977 (reaffirmed 2007) At 55 Degree C For 16 Hrs Yes
Damp Heat : In Accordance With IS:9000(part 5/sec.2)1981 At Temperature Of 40 Degree C,two Cycles Of (12+12) Hours Each 2007) Yes
Cold Test : In Accordance With IS:9000 (Part 2/Sec.4)1977 (Reaffirmed 2007) At -10 Degree C For 4 Hrs. Yes
Availability Of The Type Test Report From Central Govt. /NABL/ILAC Accredited Lab Covering All Technical Requirements. Yes
Type Test Certificate No. NA
Type Test Certificate Date NA
Name Of Lab NA
Address Of Lab NA
Supply & Commissioning NA
Warranty 1 Years