× All the transactions performed on 2.0 is available here. To access Market click "Home".

Micoprocessor Flame Photometer with Graphical Display (N and M)(NM-LT-671)

` 76,500.00

  • MRP: `85000.00

Microprocessor Flame Photometer Graphical Display Four Element measurement in a single aspiration Na, K, Li, Ca and Ba. Calibration curve fit routines first order and second order. Data displayed in concentration units i.e. ppm meq, automatic filter selection auto calibration feature. Printer attachment, PC connecting compatibility, Sample data storage more than 500 results. Alphanumeric key board for easy data entry. Graphical LCD display thus easy to read, Curve calibration using upto 5 standard, Multiple calibration curve saving facility, Stainless steel burner. Auto Gas Cut off in case of power failure. Provided with 2 Filters Compressor.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Ignition System - Auto ignition
  • Analyzed Elements - Na+, Ca++, K+, Li+
  • Accuracy - Less than +- 2 %
  • Sensitivity - Na+ = 1 ppm, Ca++ = 15 ppm, K+ = 1 ppm, Li+ = 1 ppm
  • Filters - Sodium, Potassium, Calcium, Lithium
Other Specifications Download Specification
System Is Capable To Measure Alkali And Alkaline Earth Metals (Sodium, Potassium, Calcium, Lithium) In The Samples Yes
Ignition System Auto ignition
Analyzed Elements Na+, Ca++, K+, Li+
Accuracy Less than +- 2 %
Reproducibility Less than +- 2 %
Sensitivity Na+ = 1 ppm, Ca++ = 15 ppm, K+ = 1 ppm, Li+ = 1 ppm
Display at least 3 lines LCD
Detector Photodiode
Filters Sodium, Potassium, Calcium, Lithium
Aspiration Rate 3 to 6 ml/min
Memory To store and recall 800 samples
Type Of Printer Interface For Printing Of Samples Yes
Accessories Compressor with built in air regulator and air filter
"Availability Of UL/CE Certification As Per EN 61010-1:2010 Safety Requirements For Electrical Equipment For Measurement, Control, And Laboratory Use. General Requirements " As per OEM
Power Requirements 230 V +- 10, 50 Hz AC
Operating Temperature As per OEM Degree C
Operating Humidity (RH) As per OEM %
"Test Reports For EMC/EMI As Per EN 61326-1:2013 Electrical Equipment For Measurement, Control And Laboratory Use. EMC Requirements. General Requirements (Test Reports Are To Be Furnished When Demanded By Buyer)" As per OEM
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification. (Test Reports Are To Be Furnished When Demanded By Buyer) As per OEM
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1 Year

Price Dekho Price Dekho Price List in india