digital multimeter (fluke)(fluke-87v)

` 31,500.00

  • MRP: `35076.00

4.5 Digit 20000 count True RMS Industrial Multimeter with Motor Drive Measurement Function,EN 61010-1 CAT-III 1000V / CAT - IV 600V safety rating, Accuracy - 0.05 percent, Voltage measurement - 1000V AC/DC, 10A continuous_20A for 30 sec_AC/DC Current measurement with Peak Transient capture upto 250us and 20kHz bandwidth, Special Low Pass Filter to accurately measure output at VFD,With Resistance - 50Mohm, Temperature - 1090 Deg C, Frequency - 200kHz and Capacitance - 10000 micro F, Conductance - 50nS measurement,Min, Max, Avg recording, Duty cycle and pulse width measurement, Data hold, Continuity and Diode test, Relative mode, Large backlit display with bar graph,Supplied with TL75 test leads, Statement of Calibration, Year warranty..

  • Availability: 10 In Stock
  • Min. Qty. Per Consignee: 1
  • Display - 3.5 Digit
  • Measurement Type - True RMS
  • Count - 4000
  • AC Voltage Measurement Accuracy - 0.08 %
  • AC Current Measurement - 3 Ampere
Other Specifications Download Specification
Type Hand Held
Display 3.5 Digit
Measurement Type True RMS
Count 4000
AC Voltage Measurement 600 Volt
AC Voltage Measurement Accuracy 0.08 %
DC Voltage Measurement 600 Volt
DC Voltage Measurement Accuracy 0.005 %
AC Current Measurement 3 Ampere
AC Current Measurement Accuracy 0.5 %
DC Current Measurement 3 Ampere
DC Current Measurement Accuracy 0.2 %
Resistance Measurement 40 Mega Ohm
Resistance Measurement Accuracy 0.06 %
Frequency Measurement 50 Kilo Hertz
Frequency Measurement Accuracy 100 %
Capacitance Mreasurement Range 1 to 100 Micro Fara
Capacitance Measurement Accuracy 1.5 %
Temperature Measurement -40 to 400 Degree C
Temperature Measurement Accuracy 1.5 %
Feature Of Continuity Test And Diode Test Available
Feature Of Data Logging Available
If Data Logging Feature Is Available, Internal Memory min. 5000 points 200 readings
Computer Interface Alongwith Software Available
True RMS AC Voltage Band Width 100
Safety Rating Category II 600 V of IEC 61010.
Overload Protection Through Fuse
Operating Temperature Range -20 to 55 degree C
Operating Humidity (RH) 0% - 90% (0°C - 35°C),0% - 70% (35°C - 55°C)
Power Requirements 230 V +-10 AC, 50 Hz +- 3 through Adaptor
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) UL
If Battery Operated, Type And No. Of Battery 9 volt, 01 no.
Total Voltage Of Battery 9 volt, 01 no.
Standard Accessories Supplied With The Equipment TL75 test leads,AC175 Alligator Clips, Holster,9V battery (installed),80BK temperature probe
Dimensions (H X W X L) 201 X 98 X 52 mm mm x mm x
Weight 624 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. STANDARD
Test Report Date STANDARD
Name Of The Lab STANDARD
Warranty 5 Year

Price Dekho Price Dekho Price List in india