Amprobe is sister concern company of FLUKE, AMB50 is High-Voltage Insulation Tester,Test insulation of wires, cables, transformers, motors, surge arrestors and generators, Selectable testing voltages - one testing instrument for low and high voltage systems from 500/1000/2500 and 5000V, Insulation resistance measurement up to 1T ohm, User selectable programmable timer_10s to 30 min_, Automatic discharge of test object after completion of measurement, Diagnostic tools, Polarization index _PI_, Dielectric absorption ratio _DAR_,Comparison feature to set pass/fail thresholds for quick measurement and verification, Dual power source receptacle or batteries, Built in internal memory storing 18 measurements, Comes as a complete kit power adapter, software, USB interface cable, hard carrying case, batteries, complete set of test leads, and instruction manual, CAT III 600V, 01 Year Warranty, For more details please refer technical datasheet of AMB50..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | Live circuit indicator 30 V to 600v ACDC,50 Hz |
Pass Fail Function | Yes |
Data Logging | NA |
Software | Not Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 2 milliamper |
Operating Temperature Range | -10°C~40°C Degree C |
Operating Humidity (RH) | % |
Power Requirements | Battery Operated |
Type Of Battery | 8pcs X 1.5V (LR14) batteries or power adaptor (input voltage 230V, 50/60Hz, 75mA, input DC14V, 1.0A). Power adaptor is not included. |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | Test lead,large jaw alligator clips, batteries, users manual,carrying case,software, USB cable |
Dimensions (H X W X L) | 220(L) X 155 (W) X94(H)mm mm x mm x |
Weight | 02 Kg, Including Battrery gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | Standard |
Test Report Date | Standard |
Name Of The Lab | Standard |
Warranty | 1 |