× All the transactions performed on 2.0 is available here. To access Market click "Home".

IronRemovalPlant 8000LPH forGroundWater AutoMPV, RemoteMonitoring Technology Vetted by CSIR-RDWS GOI (membrane filters)(irp 8000)

` 1,150,000.00

  • MRP: `1283000.00

Iron Removal Unit provided for ground water treatment based on aeration/oxidation based adsorption technology using specially engineered, non-toxic media followed by granulated activated carbon treatment, using food grade interconnecting piping and automatic multiport valve and remote monitoring, ideally designed, engineered and manufactured system to process 8000 LPH either on solar or grid power, technology vetted by CSIR-RDWS GOI.

  • Availability: 6 In Stock
  • Min. Qty. Per Consignee: 6
  • Prefilter Provided with Flushing Valve in the Iron Removal Unit - YES
  • Iron Removal Unit Suitable for Water Supply Equipment - Tubewell
  • Discharge Capacity of the Iron Removal Equipment - 8000 LPH
  • Diameter of Vessel of Iron Removal Equipment - 750 mm
  • Minimum Thickness of Vessel of Iron Removal Equipment - NA mm
Other Specifications Download Specification
Iron Removal Unit With
Prefilter Provided With Flushing Valve In The Iron Removal Unit YES
Iron Removal Unit Suitable For Water Supply Equipment Tubewell
Discharge Capacity Of The Iron Removal Equipment 8000 LPH
Material Of Body Of Iron Removal Equipment FRP
Diameter Of Vessel Of Iron Removal Equipment 750 mm
Height Of Vessel Of Iron Removal Equipment 1850 mm
Number Of Iron Removal Vessel 2 Nos
Minimum Thickness Of Vessel Of Iron Removal Equipment NA mm
Material Of Strainer Plate Of Iron Removal Equipment NA
Diameter Of Strainer Plate Of Iron Removal Equipment NA mm
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment NA mm
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment NA Nos
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment NA Nos
Material Of Strainer In Strainer Plate Of Iron Removal Equipment NA
Quantity Of Iron Removal Media In Iron Removal Vessel 700 Kg
Quantity Of Filter Media In Iron Removal Media 700 Kg
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel 30
Back Wash Valve In Iron Removal Vessel Automatic Operated Valve System connected to Electric Supply and operated by a timer
The Accumulated Ferric Is Removed From The Media While Back Washing YES
Maximum Iron Content Of Inlet Water 10 ppm
Maximum Iron Content Of Outlet Water 0.3 ppm
Process By Which Iron Is Removed From Water By Iron Removal Media Adsorption
Life Of Iron Removal Media 5 Years
Cost Of Refilling Of Iron Removal Media 250000 Rupees
Life Of Iron Removal Unit 10 Years
Protective Coating Of Iron Removal Vessel Inside Poly Coated
Inlet Pipe Size Of Iron Removal Unit 40 mm
Space Required For Installation Of Iron Removal Unit 7.5 Square Metres
Number Of Valves In Iron Removal Unit 3 Nos
Materal Of Valve Of Iron Removal Unit Food Grade PP
Diameter Of The Valve In Iron Removal Unit NA mm
Pressure Gauge In Iron Removal Unit YES
Pressure Release Valve In Iron Removal Unit YES
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit 4 Kg/square cm
Weight Of Iron Removal Unit 1200 Kg
Warranty Period Of Iron Removal Unit 1 Years
Arsenic Removal Unit Without
Discharge Capacity Of The Arsenic Removal Unit NA LPH
Arsenic Removal Unit Suitable For Water Supply Equipment Tubewell
Material Of Arsenic Removal Vessel NA
Diameter Of Arsenic Removal Vessel NA mm
Height Of Arsenic Removal Vessel NA mm
Minimum Thickness Of Arsenic Removal Vessel NA mm
Number Of Arsenic Removal Vessel NA Nos
Material Of Strainer Plate Of Arsenic Removal Vessel NA
Diameter Of Strainer Plate Of Arsenic Removal Vessel NA mm
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel NA mm
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate NA Nos
Material Of Strainer In Arsenic Removal Strainer Plate NA
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel NA Kg
Media Used For Removal Of Arsenic From Water NA
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel NA
Maximum Arsenic Content Of Inlet Water NA ppm
Maximum Arsenic Content Of Outlet Water NA ppm
Life Of Arsenic Removal Media NA Years
Cost Of Refilling Of Arsenic Removal Media NA Rupees
Life Of Arsenic Removal Unit NA Years
Protective Coating Of Arsenic Removal Vessel NA
Inlet Pipe Size Of Arsenic Removal Unit NA mm
Space Required For Installation Of Arsenic Removal Unit NA Square Metres
Number Of Valves In Arsenic Removal Unit NA Nos
Materal Of Valve In Arsenic Removal Unit NA
Diameter Of The Valve Of Arsenic Removal Unit NA mm
Pressure Gauge In Arsenic Removal Unit YES
Pressure Release Valve In Arsenic Removal Unit YES
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit NA Kg/square cm
Weight Of Arsenic Removal Unit NA Kg
Warranty Period Of Arsenic Removal Unit NA Years
Iron Removal Media Conform To International Standard National Science Foundation, USA
Arsenic Removal Media Conform To International Standard National Science Foundation, USA
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate YES
Field Testing Kit For Testing Iron & Arsenic Is Provided YES

Price Dekho Price Dekho Price List in india