The S820E is the highest value handheld microwave analyzer in its class, covering 1 MHz 8, 14, 20, 30, and 40 GHz. Available Vector Voltmeter allow users to easily expand the S820Es versatility at any time providing more measurement capabilities than any other similar type of product on the market today. VVM Mode with A/B and B/A Ratio capability enables the S820E to be used as a drop-in replacement for older legacy Vector Voltmeters. VVM Mode also supports Reflection/Transmission measurements directly, which eliminates the need for an external CW source, and external couplers, bridges, or splitters. Vector Error Correction can be applied to the Reflection or Transmission measurements, which provides absolute measurement data for the DUT, as well as compensating for any cables, adapters, or fixtures that might be required to connect directly. Measurement capabilities include Return Loss,VSWR,Cable Loss,Smith Chart,Phase,Distance-to-fault Return Loss, DTF and others..
Other Specifications Download Specification | |
---|---|
Description Of The Item | Two port vector network analyzers 6GHz(without spectrum analyser) |
Frequency Range | NA |
Aging Rate Of Spectrum Analyzer Frequency: Better Than 1x10-6 /Year | NA |
Frequency Counter Resolution(min.) | NA Hz |
Frequency Span | NA |
Spectral Purity:SSB Phase Noise @10KHz Offset Shall Be Less Than -90dBc/Hz At 1GHz | NA |
Spectral Purity :Harmonics @ -40 DBm Level Shall Be Less Than Or Equal To -60dBc | NA |
Sweep Time @span >or= 1 KHz | NA |
Sweep Time @span = 0 Hz | NA |
Resolution Bandwidth (-3dB) | NA |
Video Bandwidth | NA |
Amplitude : Max Input Level For Protection | NA dBm |
Amplitude : Max Input Level For Measurement | NA dBm |
Amplitude :level Measurement Uncertainity | NA dB |
Average Noise Level Displayed | NA |
Markers | NA |
Trigger | NA |
Display | TFT Colour display with provision for three traces |
Interface | USB and LAN |
Measurement Features | NA |
Software For Transfer Of Screen Shot/measurement Data To PC | Yes |
2-port Vector Network Analyzer Functionality ,for General Purpose Testing Applications In The Field,specially For Cable And Antenna Measurements, Is Available. | Yes |
Frequency Range For 2port Vector Network Analyzer | 2 MHz to 6 GHz |
Frequency Resolution (CW ON) For 2port Vector Network Analyzer | 10 Hz |
Return Loss For 2port Vector Network Analyzer | 0.00 to 60 dB |
VSWR For 2port Vector Network Analyzer | 1.01 to 10.00 |
Cable Loss For 2port Vector Network Analyzer | 0.00 to 30.00 dB |
For 2port Vector Network Analyzer: Calibration With Precision Calibration Components-open, Short, Load Should Be Included To Achieve Directivity > 35 DB | Yes |
For 2port Vector Network Analyzer: Distance-to-fault In Co-axial Cables Shall Be Possible | Yes |
Phase Range For 2port Vector Network Analyzer | -180 to +180 degree |
Phase Resolution For 2port Vector Network Analyzer | 0.01 deg |
RF Output Port For 2port Vector Network Analyzer | Type N, female, 50Ohm |
Dynamic Range For 2port Vector Network Analyzer | 60 dB |
Nominal Port Power Output For 2port Vector Network Analyzer:Hi Power/Lo-Power Selectable(power Levels Corresponding To Hi And Lo Levels Shall Be Indicated By Bidder. | High port Power 5dBm: low port power -20dBm |
Measurement Of S11 & S21 And Smith Chart Measurement Shall Be Possible | Yes |
For 2port Vector Network Analyzer :Vector Voltmeter For Comparision And Verification Of The Phase Of The Phase-matched Cables Shall Be Available | Yes |
For 2port Vector Network Analyzer:Group Delay Measurement Shall Be Possible.Details To Be Declared | Yes, Group delay range |
Operating Temperature | 5 to 40 degree C & 80 RH 40 degree C |
Power Requirement | 230 +- 10 VAC, 50Hz & External DC Input +12.5V to 15V with rechargeable battery of 1500 mAH or higher |
Warranty | 3 years |
OEM Shall Have ISO:14001 Certification For Their Manufacturing Works | yes |
One Set Of Operation And Maintenance Manual Shall Be Supplied | yes |
Standard Accessories Shall Be Supplied | yes |
Availability Of Test Reports From Central Govt/NABL/ILAC Accredited Lab Covering All The Features & Functional Requirements Including Environmental Tests As Per Specifications | yes |
Test Report No | 2160.01 |
Test Report Date | June 01, 2016 |
Name Of Lab | Anritsu Company USA |
Address Of The Lab | 490 Jarvis Drive, Morgan Hill CA 95037 |