meter bridge (accurate)(asimb)

` 990.00

  • MRP: `1100.00

The four-gap bridge shall have a large and heavy copper strip of SWG No.18 mounted on a heavy 3/4 thick laminated base of size 44x4x3/4. Nine heavy brass terminals lock type are to be provided to reduce the resistance to a minimum. The ends gaps are closed by removable brass Binding pieces, which are held in position by the terminals. The 24 SWG constantan wire is stretchedalong the top of wooden meter scale and securely clamped to the brass end strips so that end errors are negligible.Overall dimensions 1.10m x 100mm x 50mm, including terminals with superior quality spring type Brass Sliding Jockey, which moves on a metal rod, The brass strips are fitted on a laminated board of size 44x5x3/4. Includes detail working manual...

  • Availability: 100 In Stock
  • Min. Qty. Per Consignee: 25
  • DC Current Output Rating - 0 to 4 Ampere
  • Maximum Power - 120 Watt
  • Load Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 2 mV
  • Line Regulation (Voltage) ± (% of output + offset) - less than 0.01 + 1 mV
  • Over Voltage Protection Response Time - less than 10 milli sec
Other Specifications Download Specification
DC Voltage Output Rating 0 to 30 Volt
DC Current Output Rating 0 to 4 Ampere
Maximum Power 120 Watt
Load Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 2 mV
Load Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 1.5 mA
Line Regulation (Voltage) ± (% Of Output + Offset) less than 0.01 + 1 mV
Line Regulation (Current) ± (% Of Output + Offset) less than 0.05 + 0.1 mA
Over Voltage Protection Accuracy +- 0.5 + 0.5 V
Over Voltage Protection Response Time less than 10 milli sec
Ripple And Noise Voltage (20 Hz To 20 MHz) less than 1 mVrms less than 4 mVpp
Ripple And Noise Current (20 Hz To 20 MHz) less than 4 mArms
Readback Voltage Accuracy 0.05 + 10 mV
Readback Current Accuracy 0.15 + 4 mA
Readback Voltage Resolution 1 mV
Readback Current Resolution 0.1 mA
Operating Temperature 0-50 Degree C
Gperating Humidity (RH) N/A %
PC Interface USB
Dimensions N/A mm x mm x
Weight GPIB gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. N/A
Test Report Date N/A
Name Of The Lab N/A
Warranty 1 Year