The dial runs from 0 mmHg up to about 300 mmHg. You shouldnt need numbers much past 200, as even systolic pressures over 180 constitute an emergency. When you look at the dial, make sure it is at the zero baseline before starting. If it isnt, you need to calibrate it using a mercury manometer. Connect it with a Y connector, and once you move the dial over, check the pressure at several readings on both meters to make sure the aneroid manometer matches the mercury manometer..
Other Specifications Download Specification | |
---|---|
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) | Aneroid |
Conformity To Indian Standrad For SPHYGMOMANOMETERS | IS 7652 latest for Aneroid |
ISI MARKED | Yes |
CM/L No And Validity Date | 8677810 31 October 2017 |
Measuring Device | Mechnical |
Type | Portable |
Measurement Method | Auscultatory method |
Display For Digital BP Instrument: | NA for others |
Range: Pressure Measurement | 0 to 300 mmHg |
Range:Pulse Measurement For Digital With Accuracy ± 5%. | 40 to 200 per minute |
Accuracy:Pressure Measurement | ± 3 mmHg |
Pressure Detection | Capacitive Pressure sensor |
Inflation | Manual |
Deflation And Rapid Air Release | Manual |
Cuff Range | Small (18-22)cm |
Dimensions Of The Equipment | 50MM DIAL mmXmm |
Dimensions Of The Display Screen | 50MM mmXmm |
Operating Temperature | 0 to 55 °c |
Stroage Temperature | (-10) to 55 °c |
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). | Yes |
Type Of Battery(4 Nos AA Size) | Alkaline |
Automatic Power Off If System Is Idle For 3 Minutes. | Yes |
Weight | 76 GMS Kgs |
CE Marking Certificate For B.P. Apparatus Model. | Yes |
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. | Yes |
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. | Yes |
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " | Yes |
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB | Yes |
Test Cetificate No. | NA |
Test Report Date | NA |
Name And Address Of The Lab Where Test Conducted. | NA |
Others Certificate Ie ROHS,WHO,GMP Etc. | WHO GMP, CE, ISO, ISI, NSIC |
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. | Yes |
Warranty Time | 1 Year |