Model 10K-PI is a diagnostic insulation tester having test voltage range upto 10KV an Indigenous MOTWANE designed to conduct automatic diagnostic tests on high voltage equipments like Transformers, Cables, Bushings,Switchgears rotating machines. 10K-PI is microprocessor based instrument deploying latest technology very high speed data sampling to give correct, repetitive readings quality performance under harsh electrical conditions. It has wide insulation resistance range up to 20T ohm.The Information displayed on large backlit LCD display includes insulation resistance, leakage current, capacitance,battery status timer. Three programmable timers are provided to conduct various tests like Polarization Index PI,Dielectric Absorption Ratio DAR, Dielectric Discharge DD, Step Voltage SV, breakdown Voltage BDV test.10K-PI can store 1000 test results. PC interface via USB RS232for data transfer..
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Measurement Range | 200 K Ohm to 1 T Ohm |
Test Voltage | 250, 500, 1000, 2500 and 5000 Volt |
AC/DC Voltage Measurement | 600 Volt |
AC/DC Voltage Measurement Resolution | 0. 1 % |
AC/DC Voltage Measurement Accuracy | 2 % |
Auto Discharge Time | Less than 0.5 Second |
Live Circuit Detection | NA |
Pass Fail Function | Yes |
Data Logging | NA |
Software | Available |
Safety Rating | Category III 600 V of IEC 61010 |
Leakage Current | 1 milliamper |
Operating Temperature Range | 0°C to 55°C Degree C |
Operating Humidity (RH) | 95 % |
Power Requirements | Battery Operated |
Type Of Battery | NA |
PC Interface | Available |
Standard Accessories Supplied With The Equipment | No |
Dimensions (H X W X L) | 195x290x360 mm x mm x |
Weight | 5000 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM |
Warranty | 1 |