fire in your premises can destroy your expensive electronic equipment - Desktops, Laptops and more - all in a matter of minutes. Powder based extinguishers cause corrosion and irreparable damage to such sensitive and important equipment.Ceasefires cutting edge HCFC 123 Clean Agent extinguishers leave no residue, pack in mega power and are absolutely safe on sensitive electronic equipment. They use the very same extinguishing agent used at the NASA headquarters.Ceasefires Clean Agent extinguishers contain HCFC 123, one of the cleanest, most powerful extinguishing agents on the planet. They are extremely lightweight, yet packed with tremendous power and throw, to penetrate past even the finest grills and meshes.The 500 gm clean agent fire extinguishers will ensure that you are fully equipped to fight a Car or a Home fire, if there should be one. These extinguishers are easier to use than others because of their lightweight point and shoot design..
Other Specifications Download Specification | |
---|---|
Conformity To Standard | IS:15683:2006 With Latest Amdmnt. |
BIS Marking | Yes |
CM/L No. With Validity Period | 1 |
Type | Stored Pressure |
Trolley | With Trolley |
Extinguishing Media | Water Based |
Foam Based Extinguishing Media | Protein Foam(PF) |
Powder Based Extinguishing Media | BC |
Clean Agents Based Extinguishing Media | HFC |
Expellant Medium | CO2 Based |
Fire Extinguisher Capacity( Foam Based/Water Based) | 2 Ltrs |
Powder Based Fire Extinguisher Capacity | 1 Kg |
Carbon Dioxide Based Fire Extinguisher Capacity | 2 Kg |
Clean Agents Fire Extinguisher Capacity | 1 Kg |
Weight Of Filled Portable Fire Extinghuisher | 17 Kg |
Test Pressure For Foam Based/Powder(N≥20) / CO2 Based Fire Extinguisher(N≥35) | 21 Bar |
Burst Pressure,Min | 55 Bar |
Discharge Range For Class A Fire Extinguisher(≥2)/Class B (≥1) | 1 Meters |
Effective Discharge Time For Fire Extinguisher, Min | 8 Seconds |
Fire Rating For Class -A Fire Extinguisher | 1A |
Fire Rating For Class -B Fire Extinguisher | 8B |
Fire Extinguisher Suitable For Class -C Fire | YES |
Fire Extinguisher Suitable For Class -D Fire | YES |
Fire Extinguisher Suitable For Class -K Fire | YES |
Rechargebale | YES |
Color Coding | Red |
Availability Of Test Report From Central Govt./NABL/ILAC Accredited Lab To Prove Conformity To Specification | YES |
Test Report No. | nil |
Test Report Date | nil |
Name Of The Lab | nil |
Address Of The Lab | nil |
Operating Temperature | +5° C to + 55° C ° C |
Fire Extinguisher Suitable For Class -E Fire | YES |