× All the transactions performed on 2.0 is available here. To access Market click "Home".

Small attached IRP (aqualight)(HPS-IRP)

` 27,800.00

  • MRP: `34300.00

This product design to attached with single unit for Iron Removal Machine which is easy to operate and less maintenance cost.

  • Availability: 2,000 In Stock
  • Min. Qty. Per Consignee: 25
  • Prefilter Provided with Flushing Valve in the Iron Removal Unit - YES
  • Iron Removal Unit Suitable for Water Supply Equipment - Hand Pump
  • Discharge Capacity of the Iron Removal Equipment - 2000 Liter per Day LPH
  • Diameter of Vessel of Iron Removal Equipment - 1054" mm
  • Minimum Thickness of Vessel of Iron Removal Equipment - 10" mm
Other Specifications Download Specification
Iron Removal Unit With
Prefilter Provided With Flushing Valve In The Iron Removal Unit YES
Iron Removal Unit Suitable For Water Supply Equipment Hand Pump
Discharge Capacity Of The Iron Removal Equipment 2000 Liter per Day LPH
Material Of Body Of Iron Removal Equipment FRP
Diameter Of Vessel Of Iron Removal Equipment 1054" mm
Height Of Vessel Of Iron Removal Equipment 54" mm
Number Of Iron Removal Vessel 1 Nos
Minimum Thickness Of Vessel Of Iron Removal Equipment 10" mm
Material Of Strainer Plate Of Iron Removal Equipment 1
Diameter Of Strainer Plate Of Iron Removal Equipment 1" mm
Minimum Thickness Of The Strainer Plate Of Iron Removal Equipment 3 mm
Number Of Strainers For Filtration In Strainer Plate Of Iron Removal Equipment 1 Nos
Number Of Strainers For Backwash In Strainer Plate Of Iron Removal Equipment 1 Nos
Material Of Strainer In Strainer Plate Of Iron Removal Equipment UPVC
Quantity Of Iron Removal Media In Iron Removal Vessel MZ100 Kg
Quantity Of Filter Media In Iron Removal Media 12.5 KG Kg
% Free Space In The Vessel (Top And Bottom) In Iron Removal Vessel 35
Back Wash Valve In Iron Removal Vessel Inbuilt auto back wash system by manually operated valve ( pumping is not required for back wash)
The Accumulated Ferric Is Removed From The Media While Back Washing YES
Maximum Iron Content Of Inlet Water 5 ppm
Maximum Iron Content Of Outlet Water 0.3 ppm
Process By Which Iron Is Removed From Water By Iron Removal Media Delay processing System
Life Of Iron Removal Media 1 Years
Cost Of Refilling Of Iron Removal Media 17300 Rupees
Life Of Iron Removal Unit 4 Years
Protective Coating Of Iron Removal Vessel Form Coating
Inlet Pipe Size Of Iron Removal Unit 1" mm
Space Required For Installation Of Iron Removal Unit 3' Square Metres
Number Of Valves In Iron Removal Unit 1 Nos
Materal Of Valve Of Iron Removal Unit UPVC
Diameter Of The Valve In Iron Removal Unit 1" mm
Pressure Gauge In Iron Removal Unit YES
Pressure Release Valve In Iron Removal Unit YES
Maximum Line Water Pressure At Ambient Temperature In Iron Removal Unit 20 Kg/square cm
Weight Of Iron Removal Unit 15 Kg
Warranty Period Of Iron Removal Unit 1 Years
Arsenic Removal Unit With
Discharge Capacity Of The Arsenic Removal Unit 0 LPH
Arsenic Removal Unit Suitable For Water Supply Equipment Hand Pump
Material Of Arsenic Removal Vessel 0
Diameter Of Arsenic Removal Vessel 0 mm
Height Of Arsenic Removal Vessel 0 mm
Minimum Thickness Of Arsenic Removal Vessel 0 mm
Number Of Arsenic Removal Vessel 0 Nos
Material Of Strainer Plate Of Arsenic Removal Vessel 0
Diameter Of Strainer Plate Of Arsenic Removal Vessel 0 mm
Minimum Thickness Of The Strainer Plate Of Arsenic Removal Vessel 0 mm
Number Of Strainers For Filtration In Arsenic Removal Strainer Plate 0 Nos
Material Of Strainer In Arsenic Removal Strainer Plate 0
Quantity Of Arsenic Removal Media In Arsenic Removal Vessel 0 Kg
Media Used For Removal Of Arsenic From Water 0
% Free Space In The Vessel (Top And Bottom) In Arsenic Removal Vessel 0
Maximum Arsenic Content Of Inlet Water 0 ppm
Maximum Arsenic Content Of Outlet Water NA ppm
Life Of Arsenic Removal Media 0 Years
Cost Of Refilling Of Arsenic Removal Media 0 Rupees
Life Of Arsenic Removal Unit 0 Years
Protective Coating Of Arsenic Removal Vessel 0
Inlet Pipe Size Of Arsenic Removal Unit 0 mm
Space Required For Installation Of Arsenic Removal Unit 0 Square Metres
Number Of Valves In Arsenic Removal Unit 0 Nos
Materal Of Valve In Arsenic Removal Unit 0
Diameter Of The Valve Of Arsenic Removal Unit 0 mm
Pressure Gauge In Arsenic Removal Unit NO
Pressure Release Valve In Arsenic Removal Unit NO
Maximum Line Water Pressure At Ambient Temperature In Arsenic Removal Unit 0 Kg/square cm
Weight Of Arsenic Removal Unit 0 Kg
Warranty Period Of Arsenic Removal Unit 0 Years
Iron Removal Media Conform To International Standard National Science Foundation, USA
Arsenic Removal Media Conform To International Standard National Science Foundation, USA
Does The Arsenic Media Have Toxicity Leaching Characteristic Procedure Certificate YES
Field Testing Kit For Testing Iron & Arsenic Is Provided YES

Price Dekho Price Dekho Price List in india