Useful for life sciences applications, fermentation Studies, Ageing Tests, Growth Studies and biological cultures under various controlled temperature conditions.Advanced shaking mechanism provides quiet shaking and precise speed control with digital display.Minimum noise, no vibration and minimal footprint.Automatic stop of shaking system when door is opened.Stabilized orbital motion under uneven load distribution.Various configurations of stainless steel lotus clamps available for Erlenmeyer flasks.Interior made of Stainless Steel 304 grade with a drain-off-facility for spill overs.One set of lotus clamp holders with one shaking platform of stainless steel SS-304 supplied with the unit as a standard accessory.Automatic restart at preset speed in case of power failure..
Other Specifications Download Specification | |
---|---|
"Confirmatity To Standards " | CE, Eueopean Certified |
Certification No. US FDA Approved/ CE ,Eueopean Certified/BIS(CMLNo.) | CE-4356 |
Storage Capacity | 250 Ltrs |
Double Walled | Yes |
Material Of Outer Chamber | Steel Sheet with Powder Coated |
Material Of Inner Chamber | Stainless Steel (SS304) |
Insulation Material To Avoid Heat Loss | puff |
Insulation Material Thickness | 75 mm |
Temperature ,Minimum | 5 °C |
Temperature ,Maximum | 60 °C |
Temperature Resolution | 0.5 |
Temperature Uniformity | 0.5 |
Length Of Chamber,Outer | 645 mm |
Width Of Chamber,Outer | 721 mm |
Height Of Chamber,Outer | 866 mm |
Length Of Chamber,Inner | 545 mm |
Width Of Chamber,Inner | 508 mm |
Height Of Chamber,Inner | 480 mm |
Heating Power | 1500 watt |
Load Per Shelves | 2 Kg |
Adjustable Shelves Height | Yes |
Weight Of The Bacteriological Incubator | 40 Kg |
Rubber Feet (4 Nos.) To Prevent Slipping | No |
Air Ventilators On Both Side Of Wall | No |
Control Type | Microprocessor PID |
Tempertaure Control | Digital |
On-Off Switch | Yes |
Digital Indicator | Yes |
Pilot Lamp | Yes |
Audio And Visual Alarm | yes |
Auto Power Break Off | Yes |
Over Temperature Protection | Yes |
Parallel Printer Port | No |
Temperature Display | LED |
Synthetic Rubber Gasket At Door | Yes |
Door Locking Mechanism | Magnetic |
Transparant Glass Door For Viewing Specimeen Without Disturbing Inside Chamber Temp. | yes |
Warranty | 5 Years |
Availability Of Test Report From Central Govt./NABL/ILAC Acredited Lab To Prove Confirmity To All Declared Specification | CE-4356-WHO-GMP,ISO-13485-2012,ISO 9001 2008, ISO 18001-2007,ISO-14001-2004 |
Test Report No. | ERTL(N)/90(4)-2KA0308 |
Test Report Date | 11-07-2016 |
Name Of The Lab | ELECTRONICS REGIONAL TEST LABORATORY(NORTH) |
Address Of The Lab | IN HOUSE |
Digital Timer (1-9999 Min) | Yes |
Rated Volatge 220V AC, Single Phase | Yes |
No. Of Shelves | 2 |