GWINSTEK GDS-1044B features 50 MHz bandwidth, Four ranalog input channels. The maximum sampling rate for each single channel is 1GSa/s,the memory depth is 10 Mpts per channel independently. Waveform update rate is 50,000wfms/s, which helps users to precisely observe the detailed waveform variation. Additionally, 7 WVGA colour LCD display and 256 colour gradient display function together allow waveforms to be observed with the senses of transparency and gradation. With respect to the horizontal time scale adjustment knob and trigger level adjustment knob, GW Instek provides a very thoughtful design the zero key function, which allows engineers to work more effectively. For mathematical analysis mode, 1 Mpts FFT signal display makes the dull frequency domain signal analysis more delicate. Diversified trigger functions, X-Y mode analysis, and Go/NoGo function arm the GDS-1102B oscilloscope with higher level measurement technologies Prices indicated including GST. Delivery within 30Days..
Other Specifications Download Specification | |
---|---|
Type | Digital |
Operating System | Non -Windows |
Bandwidth Upgradability | No |
No. Of Analog Channels | 4 Number |
Digital Channels | No |
No. Of Digital Channels | NA Number |
Record Length Per Digital Channel Simultaneously | NA GS/sec |
Sampling Rate Per Digital Channel Simultaneously | NA Mega Points |
Min. Detectable Pulse Width | NA ns |
Memory Upgradability | No |
Segmented Memory Feature Availability | No |
Vertical Sensitivity | 500mV per Div to 10 V/div |
Vertical Resolution | 8 bits |
Coupling | AC, DC, GND |
Time Base Range | 5ns/div ~ 100s/div |
Trigger Types | Edge, Pulse Width, Video, Pulse Runt, Rise & Fall, Timeout, Alternate, Event-Delay;1~65535 events;, Time-Delay;Duration, 4nS~10S, Bus and External Trigger |
Measurements | Pk-Pk, Max, Min, Amplitude, High, Low, Mean, Cycle Mean, RMS, Cycle RMS, Area, Cycle Area, ROVShoot, FOVShoot, RPREShoot,FPREShoot, Frequency, Period, +Edges, -Edges, FRR, FRF, FFR, FFF, LRR, LRF,+Width, -Width, Duty Cycle, +Pulses, -Pulses,RiseTime, FallTime,LFR, LFF, Phase. Waveform Signal Process: Plus, -, ×, ÷, FFT, FFTrms, User Defined Expression. Cursors for Amplitude, Time, Gating available |
Frequency Analysis Feature | Yes |
In-built Frequency Counter | Yes |
In-built Function Generator | No |
Acquisition Modes | Normal, Average, Peak Detect, Single |
Display Type | Colour |
Display Size | 18 CM |
I/O Interface | USB 2.0 High-speed host port x 1, USB High-speed 2.0 device port x 1. The PC Software |
Standard Accessories To Be Supplied | Four 10X probes, Power Cord, Manual, Calibration Certificate |
Operating Temperature Range | 0°C to 50°C Degree C |
Operating Humidity (RH) | ≤80 % % |
Power Supply | 230V +- 10% , 50Hz |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : 1. Dry Heat Test : 45 Deg C For 16 Hours As Per IS:9000/Pt.3/sec.5/1977 (reaffirmed In 2007) 2. Cold Test : 0 Deg C For 4 Hours As Per IS:9000/Pt.2/sec.4/1977 (reaffirmed In 2007) 3. Damp Heat Test: 95% RH At 40 Deg C, Two Cycles Of 24 Hours Each Separated By A Gap Of 4 Hours As Per IS:9000/Pt.5/sec. 1/1991 (reaffirmed In 2007) The Oscilloscopes Shall Be Checked Functionally Before And After Recovery Period Of 1-2 Hours Of The The Environmental Test Sequence As Above. Functional Tests Shall Include Switching ON And Calibration | yes |
Test Report No. | PMR |
Test Report Date | 08/08/2017 |
Name Of The Lab | FACTORY CALIBRATION |
Warranty | 3 Year |
Real Time Bandwidth | 50 MHz |
Record Length Per Analog Channel Simultaneously | 10M maximum Mega Point |
Sample Rate Per Analog Channel Simultaneously | 1GSa/s maximum GS/sec |
Waveform Update Rate | 50000 Waveforms/ |
Time Base Accuracy | 50 PPM |