GWINSTEK GDM-8261A portable precision millimetres engages with 6 1/2 digits, dual-display, 0.012 high DC voltage accuracy and various advanced measuring function to make electrical relative signal measurement faster and easier. The standard USB Interface and USB device make the GDM-8261A an ideal tool and inexpensive solution for field service, development/maintenance, education and ATE system applications. The GDM- 8261A provides11 major measuring functions such as DCV/ACV, DCI/ACI, 2w/4w Resistance, Diode, Frequency, Continuity test and Temperature. The 0.012 DC voltage accuracy provides user the best measuring precision at the DC voltage applications. In addition, there are several advanced measuring functions such as Max, Min, dB, dBm, REL/REL, Hold, Compare and Math functions to enhance the serviceability of measuring results. Prices indicated including GST. Standard Delivery Period is 30 Days.
Other Specifications Download Specification | |
---|---|
Type | Benchtop |
Display | 6.5 Digit |
Measurement Type | True RMS |
Count | 200000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.08 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | 0.005 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.5 % |
Resistance Measurement | 40 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | NA Micro Fara |
Capacitance Measurement Accuracy | NA % |
Temperature Measurement | -50 to 1000 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 5000 points 200 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category III 600 V of IEC 61010. |
Overload Protection | Through Fuse |
Operating Temperature Range | 0°C to 50°C |
Operating Humidity (RH) | ≤80% |
Power Requirements | 230 V +-10 AC, 50 Hz +- 3 through Adaptor |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CE |
If Battery Operated, Type And No. Of Battery | NA |
Total Voltage Of Battery | NA |
Standard Accessories Supplied With The Equipment | Quick star guide , Power cord , Test lead, USB cable , CD;including complete user manual, upgrade program and PC software DMM-Viewer;, Calibration key GDM-01 |
Dimensions (H X W X L) | 265 x 107 x 350 mm x mm x |
Weight | 3100 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | PMR |
Test Report Date | 01/06/2017 |
Name Of The Lab | Factory Calibration |
Warranty | 3 Year |