No more surprises the testo 405i thermal anemometer with smartphone operation from the Testo Smart Probes series is ideal for carrying out measuring tasks in ventilation ducts. It is easy to use the anemometer to determine air velocity, temperature and volume flows. The testo 405i is also suitable for measuring indoor air velocity. Practical when, for example, you want to locate non-airtight windows. Cooling capacities and heating outputs can also be calculated when used in conjunction with the testo 605i thermohygrometer. Operation independent of measuring location via your smartphone The testo 405i hot wire anemometer combines professional Testo measuring technology with App-based operation. This means you benefit from numerous additional functions in your day-to-day work. With the testo Smart Probes App, you can view readings conveniently on your smartphone or tablet. You no longer have to spend ages trying to make out the display at poorly accessible points..
Other Specifications Download Specification | |
---|---|
Type Of Power Analyzer | Single phase |
Display Type | LCD Backlit |
Display Mode | LED Type |
Number Of Current Channels | 0 Nos. |
Number Of Voltage Channels | 0 Nos. |
Facility To Measure RMS Voltage | Available |
Measurable Voltage Range | 60 Volts |
Measurable Voltage Accuracy | 6 |
Measurable Voltage Resolution | 21 Volts |
Facility To Measure RMS Current | Available |
Measurable Current Range | 0-10 Ampere |
Measurable Current Accuracy | +-0.1 |
Measurable Current Resolution | 0.01 Ampere |
Facility To Measure Active, Reactive And Apparent Power | Available |
Maximum Power That Can Be Measured | 0.60 KW |
Power Accuracy | 5 |
Power Resolution | 120 Watt |
Facility To Measure Active, Reactive And Apparent Energy | Available |
Facility To Measure Sag(dips) And Swell(surge) | Available |
Facility To Measure Frequency | Available |
Frequency Range That Can Be Measured | NA Hz |
Facility To Measure Total Harmonic Distortion | Available |
Accuracy In Measurement Of Total Harmonics Distortion | NA |
Resolution In Measurement Of Total Harmonics Distortion | NA |
Facility To Measure Inter Harmonics | Available |
Order(n) To Which Facility To Measure Harmonics Available | NA |
Facility To Measure Power Factor | Available |
Accuracy In Measurement Of Power Factor | NA |
Facility To Measure Distortion Factor | Available |
Accuracy In Measurement Of Distortion Factor | NA |
Facility To Measure Ripple Factor | Available |
Accuracy In Measurement Of Ripple Factor | NA |
Facility To Measure Voltage And Current Unbalance | Available |
Facility To Measure Inrush Current | Available |
Facility To Measure Flicker | Available |
Facility To Measure Crest Factor | Available |
Measurable Crest Factor Range | NA |
Measurable Crest Factor Accuracy | NA |
Measurable Crest Factor Resolution | NA |
Screen Memory | NA |
Data Transfer Software Provided For Analysis On PC | Yes |
Internal Memory | 1024 MB |
Type Of Battery Used | 3AAA micro batteries |
Battery Backup | 20 Hours |
Power Supply(volts In AC) | 230 |
Weight Of The Analyser | 200 Grams |
Dimensions(LXWXH) | 10.9 x 3.7 x 3.6 cmXcmXcm |
Provision For External SD Card | Yes |
Operating Temperature Range | 0°C to +50°C degree celsius |
Operating Humidity | 21 % |
All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | Yes |
Details Of All Connecting Cables And Accessories To Be Supplied Along With The Analyzer | NA |
Compliance To IEC 61000-4-30 | Yes |
Category Of Safety Rating | NA |
Dry Heat Test As Per IS :9000(Part 3/Section 5) | Yes |
Damp Heat(cyclic Test): Two Cycles Of 24 Hours Each As Per IS: 9000(Part 5/section 1) | Yes |
Cold Test At -20 Degree C For Four Hours As Per IS: 9000(Part2 /section 4) | Yes |
Availability Of Type Test Report From Central Govt. /NABL/ILAC Accredited Lab. To Prove Confirmity To The Specification. | Yes |
Type Test Report No. | As per OEM |
TTC Report Date | As per OEM |
Name Of Lab | As per OEM |
Address Of Lab | As per OEM |
Interface | No |