The Elite 300, provides the maximum voltage output of 300V and current output 400mA, with 4 sets output terminal mainly for routine electrophoresis with nucleic acid and SDS-PAGE. With high accuracy and stable output applicable for wet transfer. Easy control Constant V/A with automatic crossover, adjustable voltage and current in minimum 1 V and 1 mA increment provide flexible condition and parameter settings. Three digits seven segments LED readout voltage, current and time. Error messages includes no load detection, sudden load change, over voltage protection, automatic recovery after power failure, short circuit, and current differential alarm for easy troubleshooting. IQ / PQ / OQ protocol is available..
Other Specifications Download Specification | |
---|---|
Types Of System | Horizontal Gel Electrophoresis system |
Applications | To separate charged molecules like DNA/RNA and proteins according to the size |
Series Of Electrophoresis | Small |
No. Of Maximum Samples Which Can Run | 10 Nos |
Body Material Of Electrophoresis Unit | Plastic/Acrylic |
Size Of Unit (WxLxH) | 12 mm |
Gel Tray Requirements | The tray should be UV proof and should have integrated fluorescent ruler which should get illuminated on exposure to UV lights for easy and safe calculation of the band movement |
Material Of Gel Tray | acrylic |
Width Of The Gel Tray | 7 cm |
Length Of The Gel Tray | 10 cm |
Thickness Of Combs And Colour Code | 1mm-white,1.5mm- Red,2mm-Blue |
All Combs Of Adjustable Height | Yes |
No. Of Wellcombs | 10 Nos |
Width Of Well,cm | 8 cm |
Length Of Well,cm | 10 cm |
Volume Of Gel,ml | 250 ml |
Type Of Electrode | Platinum |
The Base Buffer Volume,ml | 250 ml |
Details Of Other Components Included | Combs |
Required Dye Chemicals | bromophenol blue |
Specified Voltage For Dye Migration | 75 V |
Dye Migration Rate | 4.5 cm/hr |
Maxi.output Voltage Of Power Supply Unit | 300 V |
Output Current | 400 in 1 mA |
Ouput Wattage,W | 75 W |
Constant Voltage | Yes |
Constant Current | Yes |
Display | LCD display |
Control | Microprocessor controlled |
No. Of Electrode Terminal Ports | 04 Nos |
Alarm For Time Completion | Yes |
Timer Range Up To | 999 minutes |
Autostart After Power Breakdown | Yes |
Operating Voltage | 90-230 V |
Operating Temperature Range | 40 deg.C |
Power Unit Dimension (LxWxH) | 24032073 mm |
Weight Of Power Unit | 2 kg |
Warranty Period Of The System | 1 years |
Details Of Consumables To Be Supplied | NO |
Installation,commissioning And Training Part Of The Supply | Yes |