Measurement In Pressure - 0-299 mm Hg. Measurement In Pulse - 40-180 beats/minute. Accuracy In Pressure - 3 mm Hg. Accuracy In Pulse - 5 percent of Display reading. Power Input - 100 - 240 V. Power Supply. 4 x 1.5V Batteries. Cuff Circumference - 22-32 cm. Suitable For - General Aids. LCD display and is provided with just one-touch operations. The large LCD screen displays the vitals clearly and accurately. The monitor displays the systolic blood pressure, diastolic blood pressure, and pulse rate at the same time. It lets you measure your blood pressure as well as pulse within a few seconds. The machine can also detect body movements, irregular heartbeats and notifies the user of it. The BP monitor is capable of 1 memory function. ME.DI.BL.454453.
Other Specifications Download Specification | |
---|---|
Type Of SPHYGMOMANOMETERS(B.P.Apparatus) | Digital |
Conformity To Indian Standrad For SPHYGMOMANOMETERS | NA for digital |
ISI MARKED | NA for digital |
CM/L No And Validity Date | NA |
Measuring Device | Mechnical |
Type | Portable |
Measurement Method | Oscillometric |
Display For Digital BP Instrument: | NA for others |
Range: Pressure Measurement | 0 to 300 mmHg |
Range:Pulse Measurement For Digital With Accuracy ± 5%. | 40 to 200 per minute |
Accuracy:Pressure Measurement | ± 3 mmHg |
Pressure Detection | Capacitive Pressure sensor |
Inflation | Automatic Pressure Application by pump |
Deflation And Rapid Air Release | Automatic Pressure Release Valve |
Cuff Range | Medium (22-32)cm |
Dimensions Of The Equipment | 103x129x80 mmXmm |
Dimensions Of The Display Screen | 59 x 43 mmXmm |
Operating Temperature | 0 to 55 °c |
Stroage Temperature | (-10) to 55 °c |
Power Source:Chargeable 4 Nos AA Size Batteries.Operated With Battery Charger(for DIGITAL). | Yes |
Type Of Battery(4 Nos AA Size) | Alkaline |
Automatic Power Off If System Is Idle For 3 Minutes. | Yes |
Weight | 0.25 Kgs |
CE Marking Certificate For B.P. Apparatus Model. | Yes |
For Digital Sphygmomanometer ,Availability Of Type Test Reports Consisting Of Verification Of All The Features & Functional Parameters & Environmental Tests Sequences As Under: A). Dry Heat Test (For 16 Hrs At A Temp. Of 55degree C In Accordance With IS: 9000/part-3/section-3/1977)latest. | Yes |
B). Cold Test(For 4 Hrs At A Temp. Of (-10) Degree C In Accordance With IS: 9000/part-2/section-3/1977latest. | Yes |
C).Damp Heat Cyclic Test ( For 2 Cycles Of 24 Hrs At A Temp. 55 Degree C & 95% RH In Accordance With IS: 9000/part-5/section-1/1981)latest. Note:- The B.P.Instrument Shall Be Checked For All The Parameters Before Conditioning. After Completion Of The Above Environmental Tests Sequence, With A Recovery Period Of 1 To 2 Hrs, B.P.Instrument Shall Be Functional. " | Yes |
Availability Of Type Test Report Covering Complete Test Parameters As Per IS3390 Latest For Mercurial And IS7652 Latest For Aneriod Type, From Any ILAC/NABL Accredited/Central Gov. LAB.For Digital Type Including Environmental Test From Any ILAC/NABL Accredited/Central Gov. LAB | Yes |
Test Cetificate No. | NA |
Test Report Date | NA |
Name And Address Of The Lab Where Test Conducted. | NA |
Others Certificate Ie ROHS,WHO,GMP Etc. | NA |
Conformity To OILM-R-16-1 And OILM-R-16-2 For Both Non-invasive Mechanical Sphygmomanometers And Non-invasive Automated Sphygmomanometers Are For Guidance And All The Gazette Of India Related To Legal Metrology Issued Time To Time, Are Applicable To The Specification As Well As To The Product. | Yes |
Warranty Time | 3 Year |