× All the transactions performed on 2.0 is available here. To access Market click "Home".

high voltage insulation tester (kyoritsu japan)(kew-3125a)

` 120,750.00

  • MRP: `138862.00

Short-Circuit Current up to 1.5mA Diagnosis Function of PI and DAR Newly-designed alligator clip It comes with a tough hard case Filter function reduces noise interference for obtaining stable measurement Large display with Bar Graph indication and backlight Live voltage warning Safety standard IEC 61010-1 CAT IV 300V / CAT III 600V Photo 3125A.

  • Availability: 1,000 In Stock
  • Min. Qty. Per Consignee: 1
  • Measurement Range - 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
  • Test Voltage - 50, 100, 250, 500 and 1000 Volt
  • AC/DC Voltage Measurement - 600 Volt
  • AC/DC Voltage Measurement Accuracy - 2 %
  • Pass Fail Function - Yes
Other Specifications Download Specification
Type Hand Held
Measurement Range 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm 0.01 M Ohm to 10 G Ohm
Test Voltage 50, 100, 250, 500 and 1000 Volt
AC/DC Voltage Measurement 600 Volt
AC/DC Voltage Measurement Resolution 0. 1 %
AC/DC Voltage Measurement Accuracy 2 %
Auto Discharge Time Less than 0.5 Second
Live Circuit Detection NA
Pass Fail Function Yes
Data Logging more than 99 locations
Software Available
Safety Rating Category III 600 V of IEC 61010
Leakage Current 1 milliamper
Operating Temperature Range 0-40 Degree C Degree C
Operating Humidity (RH) 85 %
Power Requirements Battery Operated
Type Of Battery LR14 Alkaline battery size C × 8
PC Interface Available
Standard Accessories Supplied With The Equipment Line probe, Earth cord, Guard cord, Hook type, Power adaptor, Hard case, Instruction manual
Dimensions (H X W X L) 100 × 226 ×177 mm x mm x
Weight 4500 gms
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) Yes
Test Report No. As per OEM
Test Report Date As per OEM
Name Of The Lab As per OEM
Warranty 1

Price Dekho Price Dekho Price List in india