The Fluke 287 electronics multimeter allows you to log and zoom in on problems. Now compatible with the Fluke Connect mobile app. The Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before...
Other Specifications Download Specification | |
---|---|
Type | Hand Held |
Display | 3.5 Digit |
Measurement Type | True RMS |
Count | 50000 |
AC Voltage Measurement | 600 Volt |
AC Voltage Measurement Accuracy | 0.5 % |
DC Voltage Measurement | 600 Volt |
DC Voltage Measurement Accuracy | .05 % |
AC Current Measurement | 10 Ampere |
AC Current Measurement Accuracy | 0.5 % |
DC Current Measurement | 10 Ampere |
DC Current Measurement Accuracy | 0.2 % |
Resistance Measurement | 100 Mega Ohm |
Resistance Measurement Accuracy | 0.06 % |
Frequency Measurement | 300 Kilo Hertz |
Frequency Measurement Accuracy | 0.1 % |
Capacitance Mreasurement Range | 1 to 100 Micro Fara |
Capacitance Measurement Accuracy | 1.5 % |
Temperature Measurement | -40 to 400 Degree C |
Temperature Measurement Accuracy | 1.5 % |
Feature Of Continuity Test And Diode Test | Available |
Feature Of Data Logging | Available |
If Data Logging Feature Is Available, Internal Memory | min. 2000 points 500 readings |
Computer Interface Alongwith Software | Available |
True RMS AC Voltage Band Width | 100 |
Safety Rating | Category IV 600 V of IEC 61010 |
Overload Protection | Through Fuse |
Operating Temperature Range | -20 °C to +55 °C |
Operating Humidity (RH) | 0% to 90% (0 °C - 37 °C), 0% to 65% (37 °C - 45 °C), 0 to 45 % (45 °C - 55 °C) |
Power Requirements | Battery Operated |
Safety Certification (Certificate To Be Furnished When Demanded By Buyer) | CSA |
If Battery Operated, Type And No. Of Battery | 6 AA |
Total Voltage Of Battery | 9 V |
Standard Accessories Supplied With The Equipment | Test Leads,alligator clips, 9V Battery, excluding Temperature probe and Manual |
Dimensions (H X W X L) | 222 x 102 x 60 mm x mm x |
Weight | 870.9 gms |
Availability Of Test Reports From Central Govt / NABL Approved / ILAC Acredited Lab To Prove Conformity To The Specification Including Environmental Tests As Under : (a) Dry Heat : For 16 Hrs. At A Temp. Of 55 Degree C In Accordance With IS:9000/part-3/section-5/1977 (reaffirmed In 2007). (b) Cold Test : For 4 Hrs. At A Temp. Of -20 Degree C In Accordance With IS:9000/part-2/section-4/1977 (reaffirmed In 2007). (c) Damp Heat (Cyclic)Test : For 2 Cycles Of 24 H Each At A Temp. Of 40 Degree C & 95% RH In Accordance With IS:9000/part-5/section-1/ 1991 (reaffirmed In 2007). After Environmental Conditioning Sequence As Above And A Recovery Period Of Two Hours, The Instrument Shall Be Checked For Complete Functional Parameters, Which Should Be With In Limits.(Test Reports Are To Be Furnished When Demanded By Buyer) | Yes |
Test Report No. | As per OEM |
Test Report Date | As per OEM |
Name Of The Lab | As per OEM |
Warranty | 1 Year |